background image

Contents

1.

Introduction ...................................................

1

1.1. Gauge Probe Mounting Hole ................

1

1.2. Mounting Hole Dimension Check .........

2

2.

Installation ......................................................

3

2.1. Gauge Enclosure Rotation .....................

3

2.2. Stem Up - Stem Down Modification .....

3

2.3. Wiring (all models) ...............................

4

2.4. Terminal Connections ...........................

4

2.5. Alarm Manual/Automatic Reset Option

5

2.6. Alarm Hi/Low Modification

(alarm units only) ..................................

5

2.7. Alarm Relay Ratings ..............................

6

2.8. Power Supply Requirements .................

6

3.

Operation .......................................................

6

3.1. Zero Adjustment (all models) ...............

6

3.2. Alarm Adjustment (PG551-PG552) .....

6

3.3. Thermocouple Removal & Installation

(TPG543 & TPG553) ............................

6

4.

Integral Power Supply
(P/N 496309 or Option G115)....................

6

5.

Removal .........................................................

7

6.

Cleaning..........................................................

8

7.

Warranty and Service ....................................

8

Summary of Contents for PG 552

Page 1: ...INSTRUCTIONS FOR PLASTIC MELT PRESSURE GAUGES The following models are covered in this manual PG541 PG542 PG551 PG 552 TPG543 TPG553...

Page 2: ...erminal Connections 4 2 5 Alarm Manual Automatic Reset Option 5 2 6 Alarm Hi Low Modification alarm units only 5 2 7 Alarm Relay Ratings 6 2 8 Power Supply Requirements 6 3 Operation 6 3 1 Zero Adjust...

Page 3: ...ere abrasion dents and gouges During storage the protective cap supplied with the unit should be left in place 1 1 Gauge Probe Mounting Hole The gauge probe is machined to tight dimensional tolerances...

Page 4: ...blue Note 1 2 To prevent galling lubricate the threads with a high temperature anti seize compound 3 Insert the plug and torque lightly until seated in the well 4 Remove and carefully examine the plu...

Page 5: ...to remove excess plastic from the 0 312 diameter hole the 45 seat the 0 451 diameter and the threads A gauge plug is included in this kit 2 1 Gauge Enclosure Rotation Once installation has been compl...

Page 6: ...semble strain relief as shown in Figure 6 Attach strain relief assembly to gauge enclosure using four screws provided in kit as shown in Figure 7 2 4 Terminal Connections 5 Position Terminal Block Ala...

Page 7: ...arm i e the alarm relay resets automatically when the pressure drops back below the setpoint If manual reset is desired remove the factory installed jumper between terminals 4 and 5 Reset on the termi...

Page 8: ...ounter clockwise until the off scale indicator illuminates then clockwise slowly until this indication ceases The unit will now be calibrated 3 2 Alarm Adjustment PG551 PG552 Units equipped with an al...

Page 9: ...g four screws Detach the two 12 VDC leads going to the terminals on the short terminal block on the gauge printed circuit board and remove them from the strain relief assembly 2 Remove power supply co...

Page 10: ...imited to the replacement or repair without charge at our factory of any material or construction defect that becomes apparent within two years from the date that the products are shipped We are not l...

Page 11: ...DYNISCO PG500 Series PG500 Series Manual P N 974030 12 01 Rev C ECO 26292 DYNISCO INSTRUMENTS 38 Forge Parkway Franklin MA 02038 Tel 508 541 9400 Fax 508 541 9436...