background image

a

1  Read these instructions.

2   Keep these instructions.

3   Heed all warnings.

4   Follow all instructions.

5   Do not use this apparatus near water.

6   Clean only with dry cloth.

7   Install in accordance with the manufacturer’s 

instructions.

8   Do not install near any heat sources such  

as radiators, heat registers, stoves, or other 

apparatus (including amplifiers) that produce 

heat.

9   Do not defeat the safety purpose of the  

polarized or grounding-type plug. A    

polarized plug has two blades with one  

wider than the other. A grounding type plug  

has two blades and a third grounding  prong. 

The wide blade or the third prong are provided 

for your safety. If the provided plug does not 

fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10   Protect the power cord from being walked  

on or pinched particularly at plugs,    

convenience receptacles, and the point  

where they exit from the apparatus.

11   Only use attachments/accessories specified 

by the manufacturer.

12  

Use only with the cart, stand, tripod, 

bracket, or table specified by the 

manufacturer, or sold with the apparatus. 

When a cart is used, use caution when 

moving the cart/apparatus combination to 

avoid injury from tip-over.

13  Unplug this apparatus during lightning  storms  

 

or when unused for long periods of time.

14   Refer all servicing to qualified service  

personnel. Servicing is required when the  

apparatus has been damaged in any way,  

such as power-supply cord or plug is  

damaged, liquid has been spilled or objects 

have fallen into the apparatus, the  

 

apparatus has been exposed to rain or  

moisture, does not operate normally, or has 

been dropped.

•  This equipment should be installed near the  

 

socket outlet and disconnection of the  device  

 

should be easily accessible.

•  To completely disconnect from AC mains, 

disconnect the power supply cord from the AC 

receptacle.

•  The mains plug of the power supply shall 

remain readily operable.

•  Do not install in a confined space.

•  Do not open the unit - risk of electric shock  

 inside.

Caution:

You are cautioned that any change or 

modifications not expressly approved in this 

manual could void your authority to operate this 

equipment.

Service

•  There are no user-serviceable parts inside. 

•  All service must be performed by qualified  

 personnel.

Warning!

•  To reduce the risk of fire or electrical shock, 

do not expose this equipment to dripping or 

splashing and ensure that no objects filled 

with liquids, such as vases, are placed on the 

equipment.

•  This apparatus must be earthed.

•  Use a three wire grounding type line cord  

like the one supplied with the product.

•  Be advised that different operating voltages 

require the use of different types of line  

cord and attachment plugs.

•  Always observe the local safety regulations. 

Ensure that the factory-set power 

requirements for the device (refer to the label 

on the back of the monitor) corresponds to the 

mains supply in your region.

The lightning flash with an arrowhead 

symbol within an equilateral triangle, is 

intended to alert the user to the presence 

of uninsulated “dangerous voltage” within 

the product’s enclosure that may be of sufficient 

magnitude to constitute a risk of electric shock to 

persons.

The exclamation point within an 

equilateral triangle is intended to alert the 

user to the presence of important 

operating and maintenance (servicing) 

instructions in the literature accompanying the 

product.

IMPORTANT SAFETY INSTRUCTIONS

DBM50_prelim_2402_2012.indd   1

15-03-2012   14:36:09

Summary of Contents for DBM50

Page 1: ...DBM50 User s manual DBM50_prelim_2402_2012 indd 1 15 03 2012 14 36 07 ...

Page 2: ...DBM50_prelim_2402_2012 indd 2 15 03 2012 14 36 07 ...

Page 3: ...ed This equipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply cord from the AC receptacle The mains plug of the power supply shall remain readily operable Do not install in a confined space Do not open the unit risk of electric shock inside Caution You are cautioned that an...

Page 4: ...DBM50_prelim_2402_2012 indd 2 15 03 2012 14 36 09 ...

Page 5: ...Introduction 4 OPERATING Rear Panel Overview 5 Setting Up 6 Indicators 7 Positioning 7 MISCELLANEOUS Troubleshooting 8 Care 8 Options 8 Service 8 Technical specifications 9 TC Electronic Sindalsvej 34 DK 8240 Risskov tcdk tcelectronic com Rev 1 00 English Version DBM50_prelim_2402_2012 indd 3 15 03 2012 14 36 09 ...

Page 6: ...annels and crossover will give you unprecedented performance for many years to come It is most important however that you take a few minutes at this early stage of your DBM50 s life to read this manual It contains essential information to make you get the best from your new monitors The latest manual revision is always available at our website www dynaudioprofessional com For support please also r...

Page 7: ...e instructions on the following pages 1 Power On Off switch 2 AC power Input 3 Balanced analog input XLR 4 Unbalance analog input RCA 5 Power Mode switch 6 Remote 7 Filter switches High Pass LF Low filter setting MF Mid filter setting HF Hi filter setting 8 Level Sensitivity switch DBM50_prelim_2402_2012 indd 5 15 03 2012 14 36 11 ...

Page 8: ... proximity of boundaries so if positioned close to wall or corner use the 2dB setting If positioned far from walls use the 2dB or 0 position depending on other equipment and personal taste MF This switch sets a notch filter used to compensate for the acoustic effect of a console Such placement usually results in a response peak in lower midrange The MF switch activates a bell shaped notch filter w...

Page 9: ...he circuit when a certain threshold level is reached Positioning The DBM50 is designed as a near field monitor for stereo and surround setups The angled front plate design makes it ideal for placement on a desktop If you prefer to place the speakers on stands or on the meter bridge of a console you simply place the speaker on the sides For best results the speakers may be aimed towards the listene...

Page 10: ...e distortion occurs please turn down the level to your speakers Avoid hot plugging the equipment connected to the monitors Always turn off the speaker and other equipment when plugging or unplugging signals or switching equipment on or off Do not touch the drive units by hand The tweeter especially uses a very fine fabric dome with a ultra thin coating Options The DBM50 may be combined with a Dyna...

Page 11: ...over Frequencies 1500 Hz Crossover Slope 12 dB oct Connection XLR balanced and RCA unbalanced Recommended Placing Desktop Remarks Tweeter D 281 28 mm soft dome rear chamber magnetic fluid 4mm aluminium front Pure aluminium wire voice coil Woofer 18cm moulded aluminium frame One piece thermo formed MSP cone 75 mm voice coil with pure aluminium wire on kapton former Cabinet Designed to be placed on ...

Page 12: ...DBM50_prelim_2402_2012 indd 10 15 03 2012 14 36 15 ...