4
5
STEAM THE WEEDS AWAY
™
Triple Root Spike Technology
For weeds in the lawn, use the Triple Root Spike (TRS)
(7). Position the TRS over the center of the weed and
push it fully into the ground. Pull trigger and release
steam for approximately 5-10 seconds. The unique
design (patent pending) kills the weed by directly
attacking the root from 3 directions, at over 300°F. Move
to next weed and repeat. The TRS nozzle will only effect
the weed terminated and not the surrounding grass.
The weeds will wilt, collapse, and die within 24-48
hours.
Do not pull or dig up weed; simply leave the weed in
place to further decompose, completely.
Speed Weed Cone
For weeds and moss between paving stones, hardscape
areas, and vegetable gardens, attach the Speed Weed
Cone (8). Apply the cone over the weed. Apply the steam
trigger (2) for 5-10 seconds, move to the next weed and
repeat.
Precision Power Jet Tip
For weeds or moss in tight places with limited access,
attach the Precision Power Jet nozzle (9), point to the
weed and apply the steam for 3-4 seconds, move to the
next weed and repeat.
Precision
Power Jet Tip
Triple Root Spike
Technology
Speed Weed
Cone
GETTING ACQUAINTED
1
Handle Operation.
Locate the Steam Release Trigger (2) and Trigger Lock
(3) on the Steam Handle (1). The Lock has two positions,
OFF/LOCK, and ON. Press the front of the Trigger Lock to
lock (A), press the back of the Trigger Lock to unlock (B).
2
Releasing Steam.
When the Pressure Gauge (6) enters the red zone, your
DynaSteam is ready to go (maximum pressure = 65 PSI).
Press Green Trigger Lock (3) to the ON position (B) and
pull the Steam Release Trigger (C) to release a burst of
steam. Release trigger to stop steam.
3
Continuous Steam Operation.
To release steam for an extended period without holding
the trigger, pull trigger (D), then press the green lock in
the OFF/LOCK position (E). This will lock the valve open
and release a continuous stream of steam until the ON
button is pushed again .
Continuous steam is only recommended to release
excess steam before emptying contents.
4
After Using.
Lock trigger in OFF position to prevent accidental
operation. With trigger in open position, depress Trigger
Lock switch (3).
1)
Make sure DynaSteam is unplugged and the power is
in the OFF position (14).
2)
Unscrew Pressure Cap (5) by turning counter-clock-
wise.
3)
Using the measuring cup (10) and funnel (11), fill the
DynaSteam with up to 6 cups of water. (This will provide
approximately 35 minutes of steam)
4)
Replace the pressure cap by turning clockwise and
fasten tightly.
5)
Attach the accessory or tool you plan to use to the
Steam Handle (1).
6)
Plug the machine in and press power switch (14) to
the ON position. Two lights will illuminate. The red switch
light (14) is the power indicator. The orange heat light
(15) indicates that the machine is building up steam
pressure. When the machine is first turned on, this light
will illuminate and can take up to 10 minutes to reach
the correct pressure level depending on the amount of
water in the tank. On the pressure gauge (6), the max
pressure will be approximately 65 PSI.
The orange heat light indicator will alternate on and off
as the steam pressure is regulated. Releasing the steam
trigger will allow the steam pressure to build up.
Steaming while the pressure gauge is in the red zone
will produce good results.
If pressure falls out of the
red zone, pause steaming to regain the maximum
pressure. The steam pressure should build up again in
less than 40 seconds.
If the steam trigger is pressed under low pressure
(yellow zone of gauge), only insufficient low temperature
steam or hot water may come out.
USING DYNASTEAM FOR THE FIRST TIME
FOR BEST
RESULTS
Apply Steam For
5-10 Seconds While
Weeds Are Actively
Growing In Sunny
Dry Conditions.
TRS - Triple Root Spike
Speed Weed Cone
3. WEEDS DIE IN
24-48 HOURS
2. APPLY STEAM
Fully Trap Steam Over Weed
1. LOCATE WEED
Precision Power Jet
ENGLISH
ON/OPERATING
POSITION
CONTINUOUS
“LOCKED ON” POSITION
“LOCKED OFF”
POSITION
A
(2)
STEAM
TRIGGER
(1)
STEAM
HANDLE
(3)
TRIGGER
LOCK
(UN-LOCKED)
(3)
TRIGGER
LOCK
(LOCKED)
B
E
D
C