EC DECLARATION OF CONFORMITY 

We hereby declare that the below-reference product design, structure and our
manufacture form fulfills relevant, fundamental safety and health requirements  

with the provisions in the Council Directive on mutual approximation of laws of the  
Member States on the safety of machines

.

-

Machine directive 2006/42/EC 

-

Directive 97/23/EC European standards Pressure equipment. 

-

LVD directive 2006/95/EC

Apply conformity standards:  

-

EN60204-1 Safety of machinery – Electrical equipment of machines. 

-

CEN  EN ISO 4413:

 EN ISO 4413:2010 Hydraulic fluid power - General rules 

and safety requirements for systems and their components

.

If device has changed by someone other than at the hands of manufacturer or his
permission, this declaration is not valid. 

PRODUCT:  

 

HIGH PRESSURE DUST SUPPRESSION SYSTEMS 

ALL TYPE NUMBERS: 

HPWxxxxxxxxxx-xxxxxxx-xxxxxxx-xxxxxxxx-xxxxxxxx  

 

 

 

 

 

YLÖJÄRVI   16.04.2013 

DYNASET Oy 

Timo Nieminen 
R&D Manager  

18

April 2014 JLe 

HPW-DUST HIGH PRESSURE SUPPRESSION SYSTEMS

Summary of Contents for HPW-DUST

Page 1: ...gh pressure water mist is spayed via dust suppression nozzles round the dust particles The weight of the water bounded dust particles increases multiply that makes them fall down Low water consumption...

Page 2: ...Dust suppression system with a single water circuit 10 6 2 Close centre hydraulic system with variable displacement pump 11 6 2 1 Dust suppression system with a dual water circuit 11 6 2 2 Dust suppre...

Page 3: ...surized Prior to any cleaning inspection and service hydraulic system of your carrier machine must be stopped and all hydraulic fluid circuits depressurized Wear appropriate clothing and safety equipm...

Page 4: ...tly as necessary to suppress dust created during demolition by fallen debris by bulk loaded dump on a truck s platform etc Technically dual stage power output is implemented in two different ways 1 In...

Page 5: ...ated by the size of installed water nozzles The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression HPW90 dust double PC SAE 1 24V D200105500 HPW90 150...

Page 6: ...zle with required fittings is suitable for both continuous and intermittent high power modes Nozzles left to right No 1 4 11002 6 4 lpm 200bar 110 for intermittent high power mode No 5 and 6 2 x R3 8...

Page 7: ...kit for Open centre hydraulic systems includes pressure compensator PV SAE pos 2 1 When installing to close centre hydraulic system concerned pressure compensator is not required 2 2 Pressure reducer...

Page 8: ...s and fixed flow limiter 2 6 The High power dust suppression is switched by activating the solenoid valve 2 8 when system s operation primary hydraulic flow and secondary water flow is rated tothe fix...

Page 9: ...ulic circuit compatibility of used equipment should be ensured Hydraulic pressure and flow rate produced by hydraulic circuit should meet values demanded by your HPW pump Refer to the technical specif...

Page 10: ...d valve for high power dust suppression Water supply from water hydrant Max pressure 5 bar AN ALTERNATIVE Water reservoir intake hose filter DUST SUPPRESSION SYSTEM WITH A SINGLE WATER CIRCUIT Dual mo...

Page 11: ...pply from water hydrant Max pressure 5 bar INSTALLATION TO DIFFERENT HYDRAULIC SYSTEMS CLOSE CENTRE HYDRAULIC SYSTEMS WITH VARIABLE DISPLACEMENT PUMP DUST SUPPRESSION SYSTEM WITH A DUAL WATER CIRCUIT...

Page 12: ...the crawler track of the machinery The water supply hose must constantly be insight of an operator Water reservoir if used is recommended to lock on an excavator Water supply hose provided with filte...

Page 13: ...ivel joint is required for the water supply If there is no possibility to use swivel water joints basic dust suppression nozzles is the best place on rotating table s rim Nozzles for continuous dust s...

Page 14: ...m x 0 6 4 8 m 0 5 m 0 m 1 m 2 m 3 m 4 m NOZZLE SPRAY ANGLE THEORETICAL COVERAGE 1 1 m Pressure compensator installed to a pressure port of the main hydraulic pump An installation of a valve unit incl...

Page 15: ...nozzles and HPW pump required at least mesh 80 177 m water intake strainer Observe strainer condition regularly If any nozzle s spray form going to be varying or to be clogged the nozzle should detac...

Page 16: ...going to be varying or nozzle clogged the nozzle should detach and flush with clean water against the working flow direction Flush suction strainer with water or change it to the new one Due to small...

Page 17: ...DYNASET OY or authorized workshop all costs excluded from this warranty traveling and waiting hours daily allowance traveling expenses and uninstallation reinstallation costs will be charged from the...

Page 18: ...LVD directive 2006 95 EC Apply conformity standards EN60204 1 Safety of machinery Electrical equipment of machines CEN EN ISO 4413 EN ISO 4413 2010 Hydraulic fluid power General rules and safety requ...

Page 19: ...19 NOTES April 2014 JLe HPW DUST HIGH PRESSURE SUPPRESSION SYSTEMS...

Page 20: ...20 April 2014 JLe HPW DUST HIGH PRESSURE SUPPRESSION SYSTEMS...

Reviews: