Seals of the sealing flange differs from each other, make sure that correct
seal is installed into correct place.
13. Install sealing flanges into the piston assembly. Use lubricant to make the ins-
tallation easy.
14. Lubricate mating surfaces of the piston assembly and insert it to the body.
Place the special tool in the top of the piston assembly.