1.0  Safety Summary

 

 
High current, voltage, and rotating parts can cause serious or fatal injury. The use of electric machinery, like all other uses of 
concentrated power and rotating equipment, may be hazardous. Installing, operating, and maintaining electric machinery 
should be performed by qualified personnel, in accordance with applicable provisions of the National Electrical Code and 
sound local practices. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates 
safety standards of design, manufacture, and intended use of the instrument. Dynapar assumes no liability for the customer's 
failure to comply with these requirements. 

Rotating Machinery 

Avoid contact with rotating parts. Avoid by-passing or rendering inoperative any safety guards or protection devices. Avoid 
extended exposure in close proximity to machinery with high noise levels. Use proper care and procedures in handling, 
lifting, installing, operating and maintaining the equipment. 

Before Installation 

Safe maintenance practices with qualified personnel is imperative. Before starting maintenance procedures, be positive that, 
(1) equipment connected to the shaft will not cause mechanical rotation, (2) main machine windings have been disconnected 
and secured from all electrical power sources, and (3) all accessory devices associates with the work area have been de-
energized. If high potential insulation test is required, follow procedures and precautions outlined in NEMA standards MG-1. 

Grounding 

Improperly grounding the frame of the machine can cause serious or fatal injury to personnel. Grounding of the machine 
frame and structure should comply with the National Electrical Code and with sound local practices. Check wiring diagram 
before connecting power. 

Do Not Operate In An Explosive Atmosphere 

Do not operate the instrument in the presence of flammable gases or fumes. Operating any electrical instrument in such an 
environment constitutes a definite safety hazard. 

Keep Away From Live Circuits 

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by 
qualified maintenance personnel. Do not replace components with power cable connected. To avoid injuries, always 
disconnect power and discharge circuits before touching them. 

Do Not Substitute Parts Or Modify Instrument 

Do not install substitute parts or perform any unauthorized modification to the instrument. Introducing additional hazards is 
dangerous. Return the instrument to an authorized Dynapar representative for service and repair to ensure that safety features 
are maintained. 

Dangerous Procedure Cautions 

A CAUTION heading precedes potentially dangerous procedures throughout this manual. Instructions in the warnings 

must

 

be followed. 

 

 

 

 

 

 
 
 
 
 

Summary of Contents for SLIM Tach SL85

Page 1: ...1675 Delany Road Gurnee IL 60031 USA Customer Service Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com Technical Support Tel 1 800 234 8731 Fax 1 847 782 5277 northstar techsupport dynapar...

Page 2: ...aft Application 10 2 2 1 Encoder Frame Installation 10 2 2 2 End of Shaft Pulse Wheel Installation 10 Figure 7 Pulse Wheel Assembly 11 2 3 Electrical Installation 11 2 3 1 Quick Release Connector Hood...

Page 3: ...disconnected and secured from all electrical power sources and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required follow procedu...

Page 4: ...ntains the electronics The magnetic pulse wheel on the motor shaft has magnetic pulses imprinted on its outside surface As the motor spins the passing magnetic pulses actuate the magnetoresistive sens...

Page 5: ...able 22 AWG 8 conductor 18 length 4 twisted shield pairs Input Voltage 5 0 to 15 0 VDC Mechanical Specifications Maximum Operational Speed 5 000 RPM Nominal Air Gap 0 019 0 008 inch Shaft Axial End Pl...

Page 6: ...d insurance company Please advise us of such filing In case of parts shortages advise us immediately Dynapar cannot be responsible for any missing parts unless notified within 60 days of shipment Moto...

Page 7: ...fit over the 8 5 inch C flange encapsulated side toward the motor Mount frame onto the motor flange Insert the four 1 2 inch x 13 UNC socket head cap screws through the frame and into the motor frame...

Page 8: ...a nominal 30 inch pounds b Set Screw Style With the pulsewheel properly aligned use a 9 64 inch hex wrench to tighten 2 8 32 UNC set screws with nominal torque 3 Be sure the wheel does not have exces...

Page 9: ...NorthStar SLIM Tach SL85 Instruction Manual 9 DYNAPAR 1 800 873 8731 Figure 5 SLIM Tach SL85 End of Shaft Exploded View...

Page 10: ...sions or deformations on the motor facing or shaft If the enclosure does not fit squarely on the motor facing the alignment between the sensor module and the magnetic pulse wheel may be degraded Figur...

Page 11: ...r torque 15 foot pounds for 10 24 bolts and 30 foot pounds for 3 8 16 bolts CAUTION The pulse wheel should be seated flat against the motor shaft The wheel should not appear to wobble if the motor sha...

Page 12: ...r module is isolated from the frame of the encoder For maximum noise immunity the shield wire or pin should be connected to the shield of the cable and that of the drive or other receiving device 2 3...

Page 13: ...d from a factory representative before returning the equipment to our service department When returning an instrument for service the following information must be provided before Dynapar can attempt...

Page 14: ...031 USA Customer Service Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com Technical Support Tel 1 800 234 8731 Fax 1 847 782 5277 northstar techsupport dynapar com European Sales Representat...