background image

NorthStar RIM Tach

®

 1250 Instruction Manual

 

 4                                                                   Dynapar  (847) 662-2666                                           17 November 2008 

 

CHAPTER 1 

INTRODUCTION 

 

1.0  Safety Summary

 

 
High current, voltage, and rotating parts can cause serious or fatal injury. The use of electric machinery, like all other uses of 
concentrated power and rotating equipment, may be hazardous. Installing, operating, and maintaining electric machinery 
should be performed by qualified personnel, in accordance with applicable provisions of the National Electrical Code and 
sound local practices. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates 
safety standards of design, manufacture, and intended use of the instrument. Dynapar assumes no liability for the customer's 
failure to comply with these requirements. 

Rotating Machinery 

Avoid contact with rotating parts. Avoid by-passing or rendering inoperative any safety guards or protection devices. Avoid 
extended exposure in close proximity to machinery with high noise levels. Use proper care and procedures in handling, 
lifting, installing, operating and maintaining the equipment. 

Before Installation 

Safe maintenance practices with qualified personnel is imperative. Before starting maintenance procedures, be positive that, 
(1) equipment connected to the shaft will not cause mechanical rotation, (2) main machine windings have been disconnected 
and secured from all electrical power sources, and (3) all accessory devices associates with the work area have been de-
energized. If high potential insulation test is required, follow procedures and precautions outlined in NEMA standards MG-1. 

Grounding 

Improperly grounding the frame of the machine can cause serious or fatal injury to personnel. Grounding of the machine 
frame and structure should comply with the National Electrical Code and with sound local practices. Check wiring diagram 
before connecting power. 

Do Not Operate In An Explosive Atmosphere 

Do not operate the instrument in the presence of flammable gases or fumes. Operating any electrical instrument in such an 
environment constitutes a definite safety hazard. 

Keep Away From Live Circuits 

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by 
qualified maintenance personnel. Do not replace components with power cable connected. To avoid injuries, always 
disconnect power and discharge circuits before touching them. 

Do Not Substitute Parts Or Modify Instrument 

Do not install substitute parts or perform any unauthorized modification to the instrument. Introducing additional hazards is 
dangerous. Return the instrument to an authorized Dynapar representative for service and repair to ensure that safety features 
are maintained. 

 

 

CAUTION!:

 Crucial information that 

must

 be read and followed regarding product functioning and 

safety. 

 

 

DO THIS!:

 Additional procedure that must be read and followed for proper operation, without safety 

concerns.

 

 
 

NOTE:

 Useful information. 

 

 
 
 

QUESTION:

 Helpful hints to answer your possible questions. 

 

Summary of Contents for NorthStar RIM Tach 1250

Page 1: ...625 8 00 Outer Diameter Thru Shaft Applications Dynapar 791 1004 00 Rev C 17 November 2008 Customer Service Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com Technical Support Tel 1 800 234 8...

Page 2: ...NorthStar RIM Tach 1250 Instruction Manual 2 Dynapar 847 662 2666 17 November 2008...

Page 3: ...Wheel Alignment Check Using Straight Edge 12 2 2 5 1 Optional Pulse Wheel Alignment Check 12 Figure 8 Optional Pulse Wheel Alignment Check w Depth Gauge 12 2 2 6 Sensor Module Installation 13 Figure...

Page 4: ...s and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required follow procedures and precautions outlined in NEMA standards MG 1 Groun...

Page 5: ...onstruction and provides interchangeable sensor modules and a magneto resistive technology capable of withstanding the harshest industrial environments This ensures a precise and consistent digital mo...

Page 6: ...Gap 0 019 0 008 Shaft Axial End Play Up to 0 050 Maximum Operational Speed 7 000 RPM 120khz Enclosure Configuration 12 5 motor face or accessory flange to meet NEMA MG1 4 standards Acceleration Rate 3...

Page 7: ...to the enclosure Standard degreasing practices must be followed before applying paint Do not hinder the latches on the connector if the connector is painted If the enclosure is painted before the sen...

Page 8: ...orrosion preventative or oil to motor facing and shaft to aid assembly The pulse wheel must be well attached during rapid acceleration or deceleration of the shaft The installer may elect to drill the...

Page 9: ...3 Place assembly over the end of the shaft The wheel side with the two set screws should be toward the outside away from motor Be sure the set screws in the adapter are retracted so that they will no...

Page 10: ...will stop at the ring With a pen or some other object that will not damage the shaft work the ring around the shaft into the groove in the wheel The wheel should then completely slide on the shaft 3...

Page 11: ...ee Figure 5 2 2 5 Pulse Wheel Assembly Axial Position Adjustment If the pulse wheel is not lined up and no pre drilled holes are required use the following procedure to adjust the position of the puls...

Page 12: ...nderneath Ensure the gage is measuring the distance to the flat surface of the aluminum magnetic ring and has not engaged the edge of the steel hub or slipped past the edge of the pulse wheel 3 Repeat...

Page 13: ...o a nominal 7 5 in lbs There should not be a gap between the lip on the housing and the enclosure The stainless steel sensor module is designed to seat in metal to metal contact with the enclosure Ens...

Page 14: ...that holds the terminal block in place Remove terminal block from housing 2 Insert wiring through liquid tight flexible seal and mating connector housing Leave enough wire exposed to comfortably reac...