Start
• When starting, all operating levers must be in ”neutral position”.
• Only start the machine from the driver’s seat.
• Check the indicating instruments after start to ensure that all functions are in
order.
• Do not leave the machine unattended when the engine is running.
• When starting with battery connection cables, connect plus to plus and minus
to minus.
• Disconnect the earth (negative) first. Connect it last.
Warning
Exhaust fumes is dangerous. Ensure sufficient fresh air when starting in
closed rooms!
Hydraulic equipment
1.
Hydraulic equipment is under high pressure.
Fluids (fuel, hydraulic oil) which escape under high pressure can penetrate
the skin and cause serious injury.
Therefore immediately consult a doctor if such injury occurs. Serious infec-
tion may otherwised be caused.
2. When searching for leaks use appropriate means because of the danger of acci-
dents.
3. Before working on hydraulic equipment, de pressurize to zero and lower the
working arms of the machine.
4. When working on hydraulic equipment, switch of the engine and secure roller
against rolling away (e. g. parking brake)!
5. When connecting hydraulic cylinders and motor, pay attention to correct connec-
tion of flexible hydraulic hoses.
6. The resulting functions will be vice versa if the ports are interchanged (e. g. for-
ward or reverse), creating danger of accidents!
7. Check flexible hydraulic hoses regularly and replace them in case of damage or
wear!
The new hose or pipe must comply with the technical requirements of the ma-
chine manufacturer!
Orderly disposal or recycling of oil, fuel and filters!
General - Safety Regulations
contd.
Summary of Contents for CC102
Page 2: ...P N 35 84 70 2 Hydr Propulsion Pumps CC 102 102C 122 122C W 1012 2EN...
Page 14: ...P N 35 84 70 14 Hydr Propulsion Pumps CC 102 102C 122 122C W 1012 2EN Control device HW...
Page 15: ...P N 35 84 70 W 1012 2EN Hydr Propulsion Pumps CC 102 102C 122 122C 15 Dismantling of the pump...
Page 21: ...P N 35 84 70 W 1012 2EN Hydr Propulsion Pumps CC 102 102C 122 122C 21 Dismantling of the pump...
Page 24: ...P N 35 84 70 24 Hydr Propulsion Pumps CC 102 102C 122 122C W 1012 2EN Dismantling of the pump...
Page 32: ...P N 35 84 70 32 Hydr Propulsion Pumps CC 102 102C 122 122C W 1012 2EN Pump assembly...