P/N 35 84 70
38
Hydr Propulsion Pumps
CC 102/102C/122/122C
W-1012-2EN
HW
1
Attention!
Observe safety regulations!
Connect both control chambers with
hose NW6. Avoidance of rest signal
from hydraulic zero position.
Connect manometer to M
A
and M
B
.
Adjust zero position so that at
blocked drive both manometer
indicate the same pressure valve.
Note:
Death line of zero position.
Swiveled out to the right -
swiveled out to the left.
2
Adjustment instructions
Mechanical "zero position"