Dynamix RC 907 EV 35 User Manual Download Page 12

RC907/908-EV35 User Guide 

 

 
 
 
 

Chapter 4. Dip-switch Setup

 

 

 

 

The   configuration   dip-switch   is   on   the   front   panel   of   RC907-EV35.   (It   is   on   the 
back panel of RC908-EV35.) The definitions of the dip-switch are as follows. 

 

 

m

   The 1st bit: Duplex mode setup 

This bit is used to configure the duplex mode when the auto-negotiation at Ethernet 
interface fails. 

ON: Full duplex mode when auto-negotiation fails 
OFF: Half duplex mode when auto-negotiation fails (default) 

 

 

According to the port of user devices, this bit should be configured as follows. 

Port of User Devices

 

The 1st Bit Setup

 

Actual Working Mode

 

10/100Mbps auto-negotiation  Any 

10Mbps full duplex mode 

Forced 10Mbps half duplex 

OFF 

10Mbps half duplex mode

Forced 10Mbps full duplex 

ON 

10Mbps full duplex mode 

10Mbps full/half  duplex 
auto-negotiation 

Any 

10Mbps full duplex mode 

 

 

Since the Ethernet interface of RC907/908-EV35 works at 10Mbps full/half duplex 
mode auto-negotiation, it cannot be connected with the forced 100Mbps interface 
of other equipment. 

 

 

m

   The 2nd bit: Fault-Pass-Through function setup 
On: Fault-Pass-Through function enabled. In this case, the DSR alarm of V.35 

interface can lead to complete failure of the Ethernet port, and the link fault will be 
reported  to  the  Switch.  When  the  DSR  alarm  of  V.35  interface  disappears,  the 
Ethernet port will automatically recover. 

Off:  Fault-Pass-Through  function  disabled  (factory  default).  In  this  case,  the 

DSR alarm will not have effect on the Ethernet port. 

 

 

m

   The 3rd ~5th bit: Buffer size setup 

Since  the  bit  rate  of  V.35  interface  is  dependent  on  the  rate  of  connected  DCE 
equipment, it varies in large range. It is necessary to adjust the size of buffer. It can 

Summary of Contents for RC 907 EV 35

Page 1: ...R RC C 9 90 07 7 E EV V 3 35 5 R RC C 9 90 08 8 E EV V 3 35 5 Ethernet to V 35 Interface Converter User Guide...

Page 2: ...The Indicators on the Front Panel 4 1 3 2 The Definitions of Indicators 4 CHAPTER 2 CONNECTION CONFIGURATION 6 2 1 INTERFACE CONVERTER INTERCONNECTION 6 2 2 TYPICAL APPLICATIONS 6 2 3 DUPLEX MODE CONF...

Page 3: ...can be installed into RC series 16 slot chassis 19 3U high chassis or 4 slot chassis 19 1U high chassis or single slot chassis When installed into 16 slot or 4 slot chassis it can be mixed with other...

Page 4: ...Ethernet data frame up to 1595 bytes 4 Supports IEEE 802 3x flow control in full duplex mode 5 Supports back pressure flow control in half duplex mode 6 Built in 1k MAC address table with address fil...

Page 5: ...rnet Link ETH Data TX RX Action LNK ACT DTE PWR UTP FDX Power Supply Full Duplex Figure 2 The front panel of RC908 EV35 1 3 2 The Definitions of Indicators Ethernet Link LNK On Ethernet link is proper...

Page 6: ...The DTE connector HDB26 female connector Please refer to Chapter 3 for details of the interface definition and cable connection Ethernet interface The UTP connector Unshielded twisted pair connector f...

Page 7: ...cur The Host Site The Remote Site RC908 EV35 RC908 EV35 RC908 EV35 RC907 EV35 2 2 Typical Applications Interface Converter 10Base T V 35 DDN V 35 ase T Ethernet switch m DDN leased line is utilized to...

Page 8: ...ing different network equipment The working mode of other network equipment RC907 908 EV35 working mode 10Mbps full duplex The interface converter shall be configured to full duplex mode when auto neg...

Page 9: ...P to connect the Ethernet port of RC907 908 EV35 interface converter and make sure that the length of the UTP cable does not exceed 100m NO 1 pin NO 8 pin The pin definitions of the RJ45 interface on...

Page 10: ...5 interface adopts HDB26 female connector the definitions are as follows Pin Name Input Output Pin Number Chassis Ground CGND 1 Signal Ground GND 7 Receive Data A RD A I 3 Receive Data B RD B I 21 Rec...

Page 11: ...orking temperature 0 45 Humidity 5 90 non condensing 7 Power supply AC DC optional AC 220V 50Hz input ranges form 165 to 265V DC 48V input ranges from 36 to 72V Power consumption 5W 8 Dimensions for R...

Page 12: ...Mbps full duplex mode 10Mbps full half duplex auto negotiation Any 10Mbps full duplex mode Since the Ethernet interface of RC907 908 EV35 works at 10Mbps full half duplex mode auto negotiation it cann...

Page 13: ...etween different brands DCE equipment OFF positive phase default ON negative phase m The 7th bit RX CLK phase selection switch It provides various options for different phase relationships of receivin...

Page 14: ...switch are set to the factory default status network management software can command configure and inquire the status of the interface converter Otherwise the software has the inquiry function only A...

Page 15: ...inuously but the equipment cannot be pinged through Answer In most cases the reason is that the interface converter is connected with 100Mbps network equipment RC907 908 EV35 can only connect with 10M...

Page 16: ...onnection occurs it is abnormal Please check the operation condition of equipments To improve the network efficiency both the Ethernet equipment and the interface converter shall be set in full duplex...

Reviews: