No. 60027, Issue 4. January 1998
8 Diagnostics
10 Safety and Miisuse Warnings
57
Message
Fault and Possible Cause
Stall Timeout
Fault
Cause : The servo motor current has been at or close to
current limit for longer than the Stall Timeout
parameter value.
Action :
<
Turn the DX System off then on again. Allow
to cool down if necessary.
<
Check that steering wheels can turn freely.
Battery Low
Cause : The battery voltage is less than 17 V
Action :
<
Recharge or replace battery.
Battery High
Cause : The battery voltage is greater than 32 V
Action :
<
Check that battery charger is operating
correctly.
<
May be caused by continuous braking down a
hill at too higher speed. The problem will
occur when batteries are fully charged, fully
discharged or worn out.
Lighting SMPS
Fault
Cause : 1. A short circuit between the 13.4 V regulated
supply (if fitted) and b or -.
2. There is no power supplied to the lighting.
Action :
<
Check all lighting circuitry.
<
Check wiring as per section 5.4.3 and 5.4.4.
Head Light Fault
Cause : The circuitry for the Side Lights (front and rear)
is faulty.
Action :
<
Check for an open circuit, or a short circuit
from the Side Lights to b or -.
<
Check for blown headlight bulbs.
Left Indicator
Fault
Cause : The circuitry for the Left Indicator Light is
faulty.
Action :
<
Check for an open circuit, or a short circuit
from the Left Indicator Light to b or -
<
Check for blown left indicator bulbs.
Right Indicator
Fault
Cause : The circuitry for the Right Indicator Light is
faulty.
Action :
<
Check for an open circuit, or a short circuit
from the Right Indicator Light to b
or -.
<
Check for blown right indicator bulbs.