No. 60027, Issue 4. January 1998
7 Programming
43
Parameter
Purpose
Steer Err Reduce
Every 20 msec. the voltage at the Position Sense
Pot is checked and any error added to a
Range 50 - 95 %
Cumulative steering Error value. Prior to this
Accessed by : DCL
addition, the Cumulative Steering Error is scaled
by the Steer Err Reduce value.
The higher the Steer Err Reduce value, the more
quickly the Cumulative Steering Error is likely to
accumulate. If it goes above a preset threshold
(refer to the Steer Err Threshold parameter) a
Steering Error (SLM Flash Code 3) is produced
(refer to Diagnostics section 8).
Steer Err Threshold
If the Cumulative Steering Error reaches the Steer
Err Threshold, a Steering Error (SLM Flash
Range : 10 - 100 %
Code 3) is displayed by the SLM (refer to
Accessed
by : DCL
Diagnostics section 8).
Steer Clutch Active
Set to ‘low’ if clutch input is active low, i.e. input
is low if steering disengaged.
State : high / low
Accessed by : OEM
Set to ‘high’ if clutch input is active high.