DELAY EGRESS SYSTEM
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
OPTION WIRING
REMOTE BYPASS INPUT
Momentarily closing a normally-open dry contact
across terminals 7 & 8 will immediately release the
lock without alarm. The door will remain unlocked
until the contact is opened. Connect authorized
access/egress control(s) here (typical).
REMOTE RESET INPUT
Momentarily closing a normally-open dry contact
across terminals 5 & 6 will reset and re-lock the
3101B following delayed egress and re-closure of
door.
REMOTE TRIP INPUT
Momentarily closing a normally-open dry contact
across terminals 11 & 12 will initiate delayed egress.
This input may be used as a redundant or substitute
means of triggering delayed egress if built-in sensor
initiation is not desired (see page 10, note 3).
INPUT DESCRIPTIONS
! WARNING: DO NOT APPLY POWER TO INPUTS MARKED “ ! ” OR DAMAGE WILL OCCUR
A
C
B
D
REMOTE BYPASS INPUT TIME DELAY
Momentarily closing a normally-open dry contact
across terminals 9 & 10 will immediately release the
lock without alarm. The door will remain unlocked for a
period of time controlled by on-board adjustable timer
S2. To increase the delay rotate timer S2 clockwise.
Range is 1 to 75 seconds (~5 sec. per click).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
REMOTE
RESET
INPUT
REMOTE
BYPASS
INPUT
REMOTE
TRIP
INPUT
DELAY
EGRESS
OUTPUT
DYNST
OPTION
OUTPUT
DSM
OPTION
OUTPUT
ATS
OPTION
OUTPUT
STANDARD
INPUT/OUTPUT TERMINALS
(TYPICAL - ALL MODELS)
OPTIONAL
OUTPUT TERMINALS
(AS ORDERED)
A
B
D
E
F
G
H
3101B CIRCUIT BOARD
C
SEE PAGE 7
FOR WIRING
INFORMATION
S2
REMOTE
BYPASS
INPUT
TIME
DELAY