3101B MANUAL
02/08
MODEL 3101B
DELAY EGRESS SYSTEM
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
OPTIONAL SET-UP
- Audible Selector
The on-board audible is
normally enabled for local
signaling of lock and alarm
status. To completely disable
the audible remove jumper
(J11).
(Factory Setting)
2.
- System Selector Switches
Set the System Selector Switches (DS1) to address your specific system requirements. The normal
factory setting is all switches off.
1.
- Sensor Control
The egress sensor may
be disabled if you wish to
trigger the lock via external
remote contacts on input
terminals 11 & 12. Position
jumper (J10) to disable the
egress sensor as shown.
3.
(Factory Setting)
C
S
A
C
A
S
1
SYSTEM SET-UP
NORMAL
SET-UP MODE
2
BYPASS AUDIBLE
DISABLED
ENABLED
3
NUISANCE DELAY
1 SEC.
3 SEC.
4
EGRESS DELAY
15 SEC.
30 SEC.
SWITCH
FUNCTION
OFF
ON
MODE SETTINGS
DS1
AUDIBLE ENABLED
AUDIBLE DISABLED
REMOVE
OFF
C
ON
SENSOR ENABLED
OFF
C
ON
SENSOR DISABLED
1 2 3 4
ON
*
*
Only applies to terminals 9&10 (see next page)