INSTALL THE ARMATURE MOUNTING BRACKETS
ARMAT URE BRACKET
MOUNT ING SCREW
LOWER ARMATURE
MOUNT ING BRACKET
21/ 32”
SEX
NUT
DO OR
SPACER
ARMAT URE BRACKET
MOUNT ING SCREW
LOWER ARMATURE
MOUNT ING BRACKET
5/16”-18
THREAD
Drill an 11/32” diameter hole
through door. From sex nut
side only enlarge the 11/32”
hole to 21/32” diameter.
Drill an 11/32” diameter hole
through door. From sex nut
side only drill 1/2” diameter
hole to 1” depth.
Drill an 17/64” diameter hole
and tap for 5/16”-18 thread.
GLASS & ALUMINUM
OR HOLLOW METAL DOOR
SOLID CORE DOOR
REINFORCED DOOR
Use the gures below to identify and mark the locations of the armature mounting bracket screw holes on the door.
Refer to Template Drawing #301341 for further information.
1.
From the illustrations below select the one that resembles your door type and follow the instructions for drilling the
four (4) armature mounting bracket screw holes.
2.
Mount the armature and mounting bracket assemblies to the doors using the appropriate hardware for your door
type. Firmly tighten the mounting screws with a 3/16” hex wrench.
3.
2-3/8” FROM
CENTER OF
OPENING
ARMAT URE BRACKET
MOUNT ING SCREW
1/2”
1”
LOWER ARMATURE
MOUNT ING BRACKET
SEX
NUT
1-7/16”
FROM
HEADER
RABBET
HINGE SIDE
OF DOOR
8”
HINGE SIDE
OF DOOR
1/4” MIN
Temporarily mount the Lock Assembly to the Lock Mounting Bracket using (3) 1/4-20 x 1-1/4” socket head screws.
4.
C
L
8”
2-3/8” FROM
CENTER OF
OPENING