background image

  

 

 

 

All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors. 

 

13 

 

7) Declaration of Conformity  

 

 

 

 

                           

                    

 

This declaration of conformity is issued under the sole responsibility of the manufacturer. 

The product(s) are developed, produced and tested  according to following EC- directives:

 

 

 

2014/35/EU – Low Voltage Directive (LVD)  

 

2006/42/EU – Machinery Safety Directive  

 

2015/863/EU – RoHS Directive  

 

Applied standards: 

 

• EN 61010-1:2010  

• EN ISO 12100:2010  

• MIL-STD-810-H-2019 (Test Methods: 501.7 - High Temperature, 502.7 - Low 

Temperature, 514.8 - Vibration, 516.8 – Shock)  

 

DYNALABS MÜHENDİSLİK SANAYİ TİCARET LİMİTED ŞİRKETİ declares 

that above mentioned products meet all the requirements of the above men tioned 

standards and regulations. 

 
 
 
 
 
 

 

Murat Aykan, Technical Manager 

 

 

 

 

 

Ankara, 15.07.2021

 

 

 

 

Summary of Contents for DYN-PM-100

Page 1: ...Model DYN PM 100 100 N PM Shaker Product Manual ...

Page 2: ...yright All copyrights of this manual belonging to Dynalabs products are reserved It cannot bereproduced withoutwritten consent Disclaimer Dynalabs Ltd provides this publication as is without warranty of any kind express or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose This document is subject to change without notice and should n...

Page 3: ...acking and Inspection 4 2 2 System Components 4 2 3 Theory of Operation 4 2 4 Specifications 6 2 5 Outline Drawing 7 3 Operation and Installation 8 3 1 General 8 3 1 1 External Signal Mode 8 3 1 2 Internal Signal Mode 9 3 2 Power Requirements 10 3 3 Cooling 10 3 4 Frequency Response 11 4 Mounting Interface 11 5 Maintenance and Troubleshooting 12 6 Safety 12 6 1 Grounding 12 7 Declaration of Confor...

Page 4: ...eadequate protection for undamaged products to be transported Document the damages that occur indirectly during the transport and contact the customer representative Check all components of the shaker If there is a defect please contact us 2 2 System Components The DYN PM 100 has the following components Electrodynamic Shaker Power Adapter Signal Cable M6X10 StainlessBolt R 1 4 PneumaticUnion Prod...

Page 5: ...ority fromtheproprietors 5 DYN PM 100 has a moving coil driving coil whose current is controlled for vibration generation The stationary magnetic field is produced by a permanent magnet Item Description 1 Sine Frequency Generator 2 Gain Knob 3 External Signal Input 4 Trunnion Handle 5 Cooling Port 6 DC Power Input ...

Page 6: ... Force Shock 200 N Frequency 0 7 5 kHz Payload 1 5 kg Displacement Peak to Peak 10 mm Suspension CarbonFiber Maximum Acceleration 60 g Shaker Weight 7 2 kg Cooling System NaturalConvection For continuousoperationat 100N forced cooling is suggested Operating Temperature Range 5 35 C Maximum Input Current 6A RMS AMPLIFIER INTERNAL ExternalSignalVoltageLevel 1 VAC PEAK Power SupplyVoltage 24V DC Powe...

Page 7: ...eserved Reproduction or issueto third partiesin any formwhatsoever is notpermitted withoutwritten authority fromtheproprietors 7 2 5 Outline Drawing The dimensional properties of DYN PM 100 shakers are given below ...

Page 8: ...oprietors 8 3 Operation and Installation 3 1 General The general shaker connector configuration is given below 3 1 1 ExternalSignalMode Connect DC power source and drive signal to shaker power input and signal input respectively Start the external signal source Adjust the Gain of the amplifier by turning the Gain Knob clockwise ...

Page 9: ...1Hz to 15kHz with 1 Hz increments that the user can adjust with the Sine Frequency Generator Switch Connect DC power source and drive signal to shaker power input Pull the Gain Knob out Raise or lower the Sine Frequency Generator Switch to the desired Sine frequency Adjust the Gain of the amplifier by turning the Gain Knob clockwise The frequency of the generated sine signal will be visible on the...

Page 10: ...Power Requirements DYN PM 100 has an integrated power amplifier which is powered by its power adaptor Please note the output voltage and current ratings of the adaptor in a replacement adaptor is to be used 3 3 Cooling DYN PM 100 does not require forced cooling Air convection cooling is sufficient for the force levels given in the specifications ...

Page 11: ...rmitted withoutwritten authority fromtheproprietors 11 3 4 Frequency Response The following figure shows the acceleration levels Input voltage versus frequency of the shaker 4 Mounting Interface The shaker has seven M6 holes for DUT and fixture connection as shown in the following figure ...

Page 12: ...or proper repair 6 Safety Please ensure that this manual section is reviewed and understood prior to installation operation or maintenance of the equipment The danger of electrical shock or fire always exists in electrical equipment The DYN PM 100 Shaker is designed for safe operation Safety features such as electrical insulation on outer surfaces are provided for the safe operation of the shaker ...

Page 13: ...ested according to following EC directives 2014 35 EU Low VoltageDirective LVD 2006 42 EU Machinery SafetyDirective 2015 863 EU RoHS Directive Applied standards EN 61010 1 2010 EN ISO 12100 2010 MIL STD 810 H 2019 Test Methods 501 7 High Temperature 502 7 Low Temperature 514 8 Vibration 516 8 Shock DYNALABSMÜHENDİSLİKSANAYİTİCARET LİMİTEDŞİRKETİdeclares that abovementioned productsmeet all the req...

Reviews: