![Dyn'Aéro MCR ULC ECOLIGHT HB-WAZ Aircraft Flight Manual Download Page 21](http://html1.mh-extra.com/html/dynaero/mcr-ulc-ecolight-hb-waz/mcr-ulc-ecolight-hb-waz_aircraft-flight-manual_2546380021.webp)
19, rue de l’Aviation, F21121 Darois, FRANCE Ed.2 2009/06/2
NEXNO0901 MCR ULC
Ecolight -
Flight Manual Page
21
/
67
3.4.2. Airborne engine fire
-
Fuel valve
....................................................................................
closed
-
Full throttle until the engine stops
-
Electric fuel pump ....................................................................................
off
-
Cabin heating and ventilation ...........................................................
closed
-
Airspeed
................................................................................
134 km/h
Prepare for a forced landing with an engine inoperative.
3.4.3. Cabin fire
Extinguish the fire
Open ventilation to eliminate the smoke.
In case of an electrical fire (recognised by the smell of burning insulation) :
-
Reduce cabin ventilation
-
Master …………………………………………………………………..
off
-
Charge breaker …………………………………………………………..
pulled
LAND QUICKLY
3.5. G
LIDE
Recommended air speed ........................................................................
134 km/h
Flaps
............................................................................................
0°
Glide ratio
............................................................................................
16
3.6. L
ANDING EMERGENCIES
3.6.1. Planned forced landing with engine stopped
Choose a suitable site and report your position by radio
-
Best glide ratio airspeed ...............................................................
134 km/h
-
Flaps ....................................................................
retracted / as required
-
Belt / Safety harness ............................................................................
tight
-
Electric fuel pump ....................................................................................
off
-
Throttle setting ..................................................................................
closed
-
Magnetos
...........................................................................................
off
-
Fuel valve
....................................................................................
closed
-
Canopy
...................................................................................
unlatch
-
Master
...........................................................................................
off