background image

STANDARD PRECISION SERIES

14    Bedienungsanleitung

INHALT

Beschreibung  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Willkommen  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Auspacken und Inspektion   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Lieferumfang und Garantie  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Eigenschaften & Beschreibung  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Verantwortung des Betreibers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Bedienelemente, Anzeigen und Anschlüsse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Betriebsspannung  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Netzschalter   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Einbau  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Kühlung  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Groundlift  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LPN-Filter (Low-Pass-Notch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Betriebsart (MODE) und Verkabelung des Audio-Ausgangs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Verkabelung des Audio-Eingangs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Betrieb  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Eingangspegel-Regler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Anzeigen  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lüfter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Specifications/Technische Daten  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Summary of Contents for SL 1200 -

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Page 2: ...STANDARD PRECISION SERIES 2 Owner s Manual Bedienungsanleitung...

Page 3: ...tput Cabeling 9 Audio Input Cabeling 10 Operation 12 Volume Control 12 Indications 12 FAN Cooling 12 INHALT Beschreibung 16 Willkommen 16 Auspacken und Inspektion 16 Lieferumfang und Garantie 16 Eigen...

Page 4: ...0065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be...

Page 5: ...e as system drive for a variety of mobile and club sound systems Their comprehensive protection system includes circuitry against overheating overload short circuit HF and DC as well as back EMF and i...

Page 6: ...does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more o...

Page 7: ...and B 2 Level Indicators for channels A and B 3 Protections Indicator PROTECT 4 Power On Off Indicator POWER 5 Mains Switch 1 Mains Input 2 Ground Lift Switch CIRCUIT TO CHASSIS SWITCH 3 Type Plate 4...

Page 8: ...nd screws Brackets for securing the power amplifier are available as accessories 2 5 Ventilation As with all Dynacord power amps with fan cooling the airflow direction is front to rear obviously becau...

Page 9: ...ike stereo operation Using the input level controls on the power amp s front panel allows independently adjusting the channels amplification PARALLEL In PARALLEL mode the inputs of channel A and chann...

Page 10: ...no interfering signals are to be expected in the vicinity of the power amplifier In this case bridging the screen shielding and the pin of the inverting input inside of the connector is Speakon CHANNE...

Page 11: ...ced cabling and connections is always preferable Next to its input connector each channel provides an individual XLR type connector OUTPUT A or OUTPUT B which is connected in parallel to allow for com...

Page 12: ...evels of each channel at 40dB 30dB 20dB and 10dB below full modulation and 0dB as soon as full modulation is reached 0dB indication results from comparing the power amp s internal ratio of input to ou...

Page 13: ...STANDARD PRECISION SERIES Owner s Manual 13...

Page 14: ...Verantwortung des Betreibers 16 Installation 17 Bedienelemente Anzeigen und Anschl sse 17 Betriebsspannung 18 Netzschalter 18 Einbau 18 K hlung 18 Groundlift 19 LPN Filter Low Pass Notch 19 Betriebsa...

Page 15: ...rwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden f hren Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind au er...

Page 16: ...L Serie von Dynacord bieten eine hohe stabile Ausgangsleistung bei hohem Wirkungsgrad auf hohem Performance Niveau Sie eignen sich somit ideal als Antrieb f r eine Vielzahl von Mobil und Clubsystemen...

Page 17: ...w B 2 Pegelanzeige f r Kanal A bzw B 3 Anzeige Schutzschaltung PROTECT 4 Anzeige Betrieb POWER 5 Netzschalter 1 Netzeingang 2 Schalter Groundlift CIRCUIT TO CHASSIS SWITCH 3 Typenschild 4 Audioeingang...

Page 18: ...ntwickelt Befestigen Sie die Endstufe an der Vorderseite mit 4 Schrauben und Unterlegscheiben wie in folgender Abbildung dargestellt Wird das Rack in dem die Endstufe eingebaut ist transportiert muss...

Page 19: ...R ckseite bestimmt die Betriebsart der Endstufe M gliche Schalterstellungen sind DUAL PARALLEL und BRIDGED DUAL In der Betriebsart DUAL arbeiten beide Kan le der Endstufe unabh ngig voneinander Diese...

Page 20: ...tsprechern die im aktiv 2 Weg Betrieb verwendet werden Bi Amp Die korrekte Anschlussweise f r diese Betriebsart ist zus tzlich auf der Endstufe selbst abgebildet BRIDGED In der Betriebsart BRIDGED wer...

Page 21: ...er Netzzuf hrungen HF Steuerleitungen usw ist jedoch eine symmetrische Verkabelung immer zu bevorzugen Zus tzlich zu den Eing ngen steht f r jeden Kanal jeweils eine parallel geschaltete XLR Buchse OU...

Page 22: ...renze erreicht ist Die 0 dB Anzeige wird endstufenintern aus einem Vergleich von Ausgangsspannung zu Eingangsspannung gewonnen und zeigt somit pr zise die Aussteuerungsgrenze an noch bevor eine h rbar...

Page 23: ...ge Gain ref 1 kHz 32 0 dB Input Sensitivity rated power 8 1 kHz 2 2 dBu 1 0 Vrms 3 1 dBu 1 11 Vrms 5 1 dBu 1 39 Vrms 6 6 dBu 1 66 Vrms THD at rated output power MBW 80 kHz 1 kHz 0 03 IMD SMPTE 60 Hz 7...

Page 24: ...STANDARD PRECISION SERIES 24 Owner s Manual Bedienungsanleitung Block Diagram Blockschaltbild...

Page 25: ...STANDARD PRECISION SERIES Owner s Manual Bedienungsanleitung 25 Dimensions Abmessungen...

Page 26: ...Notes...

Page 27: ......

Page 28: ...tems Telex EVI Audio Shanghai Ltd Room 3105 3109 No 1 Building No 218 Tian Mu West Road Shanghai China PC 200070 Phone 86 21 6317 2155 Fax 86 21 6317 3023 Europe Africa Middle East Germany Bosch Commu...

Reviews: