background image

DIGITAL SYSTEM AMPLIFIER

Owner‘s Manual    13

2.10 Audio Cabling

Input

Inputs are electronically balanced. Whenever possible, using balanced audio signal feeds at the input of the power amplifier is
always preferred. Unbalanced connections should only be used if the cables are very short and no interfering signals are to be
expected in the vicinity of the power amplifier. In this case, bridging the screen (shielding) and the pin of the inverting input
inside of the connector is mandatory. Otherwise, a 6 dB drop in level could result. Please also see following illustration. Due to
their immunity against external interference sources, such as dimmers, mains connections, HF-control lines, etc., using
balanced cabling and connections is always preferable.

Output in DUAL Mode or PARALLEL Mode

See illustration right for connecting speakers in DUAL or PARALLEL mode.
Only connection of CH 1 and CH 2 is shown, the other channels have to be
connected identically.
The correct connection is also indicated at the amplifiers rear panel.

Output in BRIDGED Mode

See illustration right for connecting speakers in BRIDGED mode. Only connection
at CH 1/CH 2 is shown, the other channels have to be connected identically.
The correct connection is also indicated at the amplifiers rear panel.

Illustration 2.8: Balanced / unbalanced connection of input

CAUTION: 
In BRIDGED mode operation, it is not allowable for the load connected to fall below the values
given in table 2.2 on page 9. Extremely high voltages can be present at the output. The con-
nected speaker systems must be able to handle such voltages. Make sure to completely read
and fully observe power rating specifications of the speaker systems to be used and to check
them against the output power capacity of the power amp.

Summary of Contents for DSA 8405

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Page 2: ...MOTE 14 Options 15 RCM 810 15 INHALT Einf hrung 20 Auspacken und berpr fen 20 Lieferumfang und Garantie 20 Verantwortung des Betreibers 20 Installation 21 Bedienelemente Anzeigen und Anschl sse 21 Bet...

Page 3: ...0065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be...

Page 4: ...gh power output that might be dangerous for human beings as well as for the connected speaker systems High output voltages can damage or even destroy the connected speaker systems especially when the...

Page 5: ...locate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult...

Page 6: ...Off Indicator POWER 5 Standby Indicator STANDBY 6 Remote Amplifier Indicator IRIS Net 7 Mains Switch 1 Mains Input 2 POWER REMOTE connector POWER REMOTE 3 Power On Delay selection switch ON DELAY 4 Po...

Page 7: ...fectively suppressing any possible power on noise which otherwise might be heard through the loudspeakers 2 4 Mounting DSA amplifiers have been designed for installation in a conventional 19 inch rack...

Page 8: ...and DSA 8410 allow the configuration of audio inputs CH 1 CH 2 or CH 3 CH 4 the amplifier type DSA 8805 additionally allows configuration of audio CH 5 CH 6 or CH 7 CH 8 In the following description...

Page 9: ...control of channel A only BRIDGED operation is the mode of choice whenever high power speakers are used Illustration 2 2 Audio signal applied to input A connector in PARALLEL mode CAUTION In PARALLEL...

Page 10: ...mode the power amplifier reaches maximum output power having a load of 2 connected Up to 4 cabinetts having a nominal impedance of 8 each can be driven by each amplifier channel This mode should be us...

Page 11: ...ividual amplifier channels via Variable Load Drive VLD For power amplifier models DSA 8405 and DSA 8805 it is possible to freely select the output power in a range between 100 watts to 500 watts for l...

Page 12: ...SA 8410 or Bridge 2 DSA 8x05 Bridge 4 DSA 8x05 or Bridge 2 DSA 8410 2000 W Bridge 2 DSA 8410 Bridge 4 DSA 8410 Table 2 3 Maximum Output Power VLD deactivated 2 4 8 125 W VLD all types VLD all types 2...

Page 13: ...Mode See illustration right for connecting speakers in DUAL or PARALLEL mode Only connection of CH 1 and CH 2 is shown the other channels have to be connected identically The correct connection is als...

Page 14: ...rated dynamic audio limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term blinking is not a problem because the internal limiter...

Page 15: ...the IRIS Net Intelligent Remote Integrated Supervision software package All operational states e g power on status temperature activation of protections load impedance etc are centrally registered an...

Page 16: ...module does not appear in the system even though it is physically connected to the CAN bus Illustration 4 1 Controls and Connections of the RCM 810 CAUTION All RCM 810 parameters configured via IRIS...

Page 17: ...etworks reducing the data rate becomes necessary down to the minimum data rate of 10 kbit s The following table illustrates the relation between data rate and bus length or network size The use of CAN...

Page 18: ...100 V Power Bandwidth THD 1 ref 1 kHz half power rated load 10 Hz 25 kHz 50 Hz 25 kHz Voltage Gain ref 1 kHz 32 dB 32 dB 32 dB 33 dB 36 dB Input Sensitivity rated power 1 kHz 0 775 V 0 0 dBu 1 1 V 3...

Page 19: ...andwidth THD 1 ref 1 kHz half power rated load 10 Hz 25 kHz 50 Hz 25 kHz Voltage Gain ref 1 kHz 32 dB 32 dB 32 dB 33 dB 36 dB Input Sensitivity rated power 1 kHz 1 1 V 3 0 dBu 1 55 V 6 0 dBu 1 55 V 6...

Page 20: ...dwidth THD 1 ref 1 kHz half power rated load 10 Hz 25 kHz 50 Hz 25 kHz Voltage Gain ref 1 kHz 32 dB 32 dB 32 dB 33 dB 36 dB Input Sensitivity rated power 1 kHz 0 775 V 0 0 dBu 1 1 V 3 0 dBu 1 1 V 3 0...

Page 21: ...370 4x225 470 1604 Alert Alarm Mode 3dB 4 1 4 230 8 4 1280 4x225 380 1297 Alert Alarm Mode 3dB 70 V 100 V1 70 V 100 V 230 7 6 1140 4x225 240 819 DSA 8410 Output Mode Umains in V Imains in A Pmains in...

Page 22: ...ax Output Power 70 V 100 V2 70 V 100 V 230 5 6 800 8x63 296 1010 1 3 Max Output Power 2 2 2 230 12 8 2045 8x167 709 2419 1 3 Max Output Power 4 2 4 230 12 2 1920 8x167 584 1993 1 3 Max Output Power 70...

Page 23: ...DIGITAL SYSTEM AMPLIFIER 38 Owner s Manual Bedienungsanleitung Block Diagram Blockschaltbild...

Page 24: ...DIGITAL SYSTEM AMPLIFIER Owner s Manual Bedienungsanleitung 39 5 2 Dimensions Abmessungen...

Page 25: ...unications Systems Telex EVI Audio Shanghai Ltd Room 3105 3109 No 1 Building No 218 Tian Mu West Road Shanghai China PC 200070 Phone 86 21 6317 2155 Fax 86 21 6317 3023 Europe Africa Middle East Germa...

Reviews: