Figure 5.4: DPC 8120
Number
Element
Description
1
EXT interface
Connection for DPC 8120 call station extension
2
PCA BUS interface
Connection to PROMATRIX 8000 CONTROLLER
3
LINE/PTT interface
Connection for external audio devices or a PTT button
4
MIC interface
Connection for external microphone
5
EXTENSION
ADDRESS
DIP switch for setting the address of the call station
extension
Delivery condition
The call stations are programmed with the following factory functions and properties settings:
Parameters
Setting/description
CAN address
0 (disconnected)
Name
DPC 8015
Password
Setup menu password-protected, default
password: 2222
Opening gong
Off
Buzzer
On (acoustic warning signal)
Compressor
Off
Options
Alarm buttons
Not configured
5.3