Dynaswivel
®
Swivels 360° at two locations which allows an
air hose to drop straight to the floor, no matter
how the tool is held.
•
94300
Composite Swivel 1/4" NPT.
•
95461
3/8" NPT.
•
95462
1/2" NPT.
96007 Motor Tune-Up Kit
•
Includes assorted parts to help
maintain motor in tip-top shape.
Optional Accessories
Disassembly/Assembly Instructions (continued)
7.
Apply Hernon #940 PST Pipe Sealant (or equivalent) to threads of inlet bushing and install muffler assembly onto valve body (torque 23.0 N•m/200 in. - lbs.).
8.
Install throttle lever and
12132
Pin. Remove from vise.
Tool Reassembly is complete. Please allow 30 minutes for adhesives to cure before operating tool.
Important:
Motor should now be tested for proper operation at 90 PSI. If motor does not operate properly or operates at a higher RPM than marked on the
tool, the tool should be serviced to correct the cause before use.
Loctite® is a registered trademark of Loctite Corp.