background image

 

RP400/RP800/RP1600 
Power Packs 

3 .  

1.

 

AC  On  /  Off  Power  Switch  -  Turns  power 
pack on and off. Also offers a dual propor-
tional  dimmer  slide  switch  for  modeling 
light control,  including Full Off,  so that  the 
cooling fan can continue to run. 

2.

 

Two  stop  Variator  Control  -  Fine-tune  your 
power  settings  in  0.2  stop  detented  incre-
ments.  Used  in  combinations,  the  power 
control switches and Variator provide a total 
of  15 different  power  settings with  a  single 
flash head. 

3.

 

Power  Control  Switches  –  Three  position 
full/half/quarter  power  switches  provide 
power settings over a three stop range per 
channel.  (These  can  be  trimmed  using  the 
Variator or combined using the Ratio output 
switch.) 

4.

 

Flash  Head  Outlets  –  The  RP  packs  are 
capable of accepting up to three heads. All 
outlets are arc protected. This means that it 
is completely safe to plug and unplug flash 
head cables into the outlets even while the 
pack is on. 

5.

 

AC Power Cord Socket and Circuit Breaker - Offers easily rest-able protection. 

6.

 

Ratio/Combined Output Switch - An indicator light tells you whether your power is routed symmetrically or asymmetrically 
between the “A” and “B” flash head outlet banks. 

7.

 

Sync Input Socket – ¼” Phono style jack for plugging in sync cord, slave or optional radio slave. 

8.

 

Ready Light/Test Switch - When lit the pack is fully charged. This button can also be used to manually trigger the pack. 

9.

 

Audible Ready Indicator Switch- Get audible confirmation that the pack is fully recycled to full power

 

5. (back) 

2. 

4. 

6. 

1. 

9. 

8. 

7. 

Summary of Contents for MP1600

Page 1: ...power pack instruction manual Dyna Lite ...

Page 2: ...tion or in a shipping case Extended Life of Dyna Lite power packs insure a longer continuous duty life cycle and more stamina than competitive systems Flexibility and Control built into sensibly priced Dyna Lite power packs simplify complex lighting set ups Abuse Resistant Design through the use of arc proof connectors and switches make Dyna Lite equipment safe and virtually assistant proof Reliab...

Page 3: ...ang on or touch hot surfaces 8 To avoid electrical shock hazard DO NOT attempt to disassemble the power pack Incorrect reassembly could cause an electrical shock hazard when a power pack is subsequently used Take it to a qualified Dyna Lite service technician when repair is required 9 When the power pack is not in use for one month or more it is wise to periodically plug the power pack in and turn...

Page 4: ...ower Power Control Switches can be adjusted to provide full half or quarter power to the flash head outlets in the respective A or B channels Ratio Combined Switch All Dyna Lite power packs feature the Ratio Combined switch On all packs the flash head outlets are grouped into two separate channels sometimes called banks marked A and B The switch has two options the first is A B and the second is A...

Page 5: ...ine tune the light balance between packs There are many times for example where adjusting a single light an entire stop will result in too dramatic a change NOTE When increasing the power with the Variator Control the flash output is adjusted automatically When decreasing the power bleed the pack by pushing the test fire button Sync Slave Infrared Radio Operation The Sync Input Socket circuitry is...

Page 6: ...ans that it is completely safe to plug and unplug flash head cables into the outlets even while the pack is on 6 Modeling Light Delay Circuit SP1600 only Delays the modeling light from coming back on after flash for 1 2 4 or 8 seconds It is especially useful when you are dragging the shutter so the modeling lights will not effect exposure It also redirects the power from the pack when recycling as...

Page 7: ...d using the Ratio output switch 4 Flash Head Outlets The RP packs are capable of accepting up to three heads All outlets are arc protected This means that it is completely safe to plug and unplug flash head cables into the outlets even while the pack is on 5 AC Power Cord Socket and Circuit Breaker Offers easily rest able protection 6 Ratio Combined Output Switch An indicator light tells you wheth...

Page 8: ...MH2065v MP800 RP1600 MK8 1222v Lighting Kit ...

Page 9: ...f the subject when you are using multiple lights to understand the ratios between the lights Some meters are reflective meters often referred to as spot meters and measure the light being reflected back from the subject taken from the camera position Halving and Doubling Photography is based on the principle of halving and doubling Shutter speeds are expressed this was as well as the amount of lig...

Page 10: ...ide the umbrella s interior surface If you place the light too close to the umbrella you are not taking advantage of the broad source your umbrella offers Next position the umbrella off to one side of your subject to create dimension fig 1 A Start at three or four feet away for a basic head and shoulders portrait and slightly above the subject pointing slightly down fig 2 A Experiment with the ang...

Page 11: ...the Wein slave energizes Modeling light doesn t work There is a power switch on the back of the Dyna Lite head This switch controls the power to the modeling light If this switch is off the modeling light will not work independent of how the pack is set If head switch is on and the modeling light switch from the pack is on check and make sure that the cables are properly seeded If they are it is l...

Page 12: ... 10 10 10 10 10 F slop Range 6 6 6 6 6 Vanator Range in 0 2 stop adjustments 2 2 2 2 2 Built in WEIN slave yes yes yes no yes es POCKETWIZARD recei ver yes no Yes no Yes no no yes Maximum heads allowed 4 3 4 3 4 3 3 4 Dimensions 5 7 8 x 6 7 8 5 7 8 x 6 7 8 5 7 8 x 6 7 8 5 716 x 6718 71 EV x 9 114 149mm x 175 mm 149 mm x 175mm 149 mm x 175mm 149fern x 235mm 1 el elm x 235 mm Height including handle...

Reviews: