H

Maintenance

Never attempt to 
service heater while 

it is connected to natural gas supply, 
operating, or hot. Severe burns can occur.

1. Always keep heater clean. 
2. Inspect heater before each use.  

Check connections for leaks. Apply  
a 50/50 solution of dish soap and 
water. Bubbles forming show a leak 
that must be corrected. Correct leaks 
at once.

3. Inspect regulator hose assembly 

before each use. If hose is highly 
worn or cut, replace with hose 
specified by manufacturer.

4. Keep appliance area clear and free 

from combustible materials, gasoline, 
and other flammable vapors and 
liquids.

5. Have heater inspected yearly by a 

qualified service person.

6. The flow of combustion and 

ventilation air cannot be obstructed.

STORAGE

Disconnect heater 
from natural gas 

supply.

1. Place plastic cover over brass fitting 

on inlet connector.

2. Store in a dry, clean, safe place.
3. When taking the heater out of 

storage, always check inside the 
heater. Small animals or insects may 
place foreign objects in the heater. 
Keep heater free from foreign objects 
and combustible materials.

Dyna-Glo

®

 Delux Natural Gas 

Radiant Heaters

RA100NGDGD and RA250NGDGD

Dyna-Glo Delux Operating Instructions and Parts Manual

Symptom 

Possible Cause(s) 

Corrective Action

Burner fails to light

Burner lights but goes out 
when automatic control 
valve button is released

Burn rate is low, emitter 
does not glow

Flames are extremely high 
and coming from emitter

1.  More warm-up time needed 

2.  Gas pressure is low
3.  Thermocouple loose or in need of 

replacement

4.  Automatic control valve in need of 

replacement

1.  Main burner valve not completely open 

2.  Clogged gas orifice
3.  Low gas pressure
4.  Low gas supply
1.  Main burner valve not fully open 

 

2.  Plugged gas orifices
3.  Low gas pressure
4.  Low fuel supply
Unit has been connected to a propane gas 
supply instead of natural gas

1.  Relight, holding control valve button in for 

45 seconds

2.  Inspect natural gas supply
3.  Tighten, reconnect or replace 

thermocouple

4.  Replace automatic control valve 

1.  Completely open main burner valve by 

turning control knob to HIGH position

2.  Replace gas orifice
3.  Check gas supply, regulator function
4.  Contact gas supplier
1.  Fully open main burner valve by turning 

control knob towards HIGH position until it 
stops

2.  Replace gas orifice
3.  Check gas supply, regulator output
4.  Consult gas supplier
Check gas source and replace with natural gas 
supply

Troubleshooting Chart

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

E

N
G

L

I

S

H

E

N
G

L

I

S

H

Summary of Contents for RA100NGDGD

Page 1: ...s heater If you need assistance or heater information such as an instruction manual labels etc contact your local manufacturer Consumer Retain this manual for future reference Dyna Glo Delux Natural G...

Page 2: ...ntenance method you use Carbon Monoxide poisoning may lead to death Some people are more affected by Carbon Monoxide than others Early signs of carbon monoxide poisoning resemble the flu with headache...

Page 3: ...ious or fatal injury Assembly MODEL RA100NGDGD 1 Provide natural gas supply system 2 Install plumbing to a low pressure natural gas source to heater The source must be regulated to 1 2 PSI maximum 3 4...

Page 4: ...o the OFF position 2 Firmly close the natural gas supply valve TO RESTART HEATER 1 Wait five minutes for heater to cool 2 Follow steps in TO START HEATER section TO START HEATER RA250NGDGD 1 Follow al...

Page 5: ...k NFPA54 ANSI Z223 1 or the Natural Gas Installation Code CAN CSA B149 1 VENTILATION A three square foot opening of fresh outside air for each 100 000 BTU Hr of heater output must be provided to opera...

Page 6: ...0NGDGD Dyna Glo Delux Operating Instructions and Parts Manual Symptom Possible Cause s Corrective Action Burner fails to light Burner lights but goes out when automatic control valve button is release...

Page 7: ...ll 1 877 447 4768 Please provide following information Model number Serial number if any Part description and number as shown in parts list Figure 6 Repair Parts Illustration for Natural Gas Radiant H...

Page 8: ...Base 5002851 1 14 Control Knob 2101451 1 15 Control Valve 5050651 1 16 Fitting 2304948 2 17 Tubing Inlet Assy 2315524 1 18 Fitting Regulator to Tubing Inlet 2315547 1 19 Regulator 2315555 1 20 Regula...

Page 9: ...3 14 15 16 17 18 19 20 4 5 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 38 39 40 41 For Technical Support or Troubleshooting Call 1 877 447 4768 8 00 am 5 00 pm CST www ghpgroupinc com For Repai...

Page 10: ...5536 1 25 Regulator Connector 2315547 1 26 Inlet Tubing Assy 2315542 1 27 Connector 2315549 1 28 Control Valve 5001423 1 29 Contol Valve Fixing Nut 2305687 1 30 Contol Valve Bracket 2315538 1 31 Ball...

Page 11: ...MAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or cons...

Page 12: ...u can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here Tel...

Reviews: