Operation

Hot while in 
operation. Do not 

touch. Keep children, clothing, furniture, 
gasoline, and other liquids having 
flammable vapors away.

The gas supply attaches to the heater by 
a minimum 3/8 inch I.D. pipe or flexible 
connector. User must supply pipe or 
flexible connector. The length should be 
no more than 10 feet. The natural gas 
moves through the regulator and out 
the nozzle.

Ignition System:

 The ignitor initiates 

a spark which ignites the gas from the 
main burner.

Automatic Control System:

 This 

system causes the heater to turn off if 
the flame is extinguished.

TO START HEATER (RA100NGDGD)

1. Follow all of the safety, ventilation 

and installation instructions 
previously noted in this manual.

2. Always be sure to place the heater on 

a stable and level surface while the 
heater is in operation. Be sure that no 
strong winds blow into the ends of 
the heater.

3. Turn control knob CLOCKWISE 

 

to “OFF” position.

4. Turn natural gas supply valve on.
5. Depress heater control knob and turn 

counterclockwise to “(IGN) LOW” 
position to light burner (see Figure 3).

6. If burner does not light, turn heater 

control knob to “OFF” position and 
repeat step 5. Keep control knob 
depressed for approximately 10 to 15 
seconds, then release control knob.

7. If burner flame goes out, wait 5 

minutes then repeat steps  5 and 6. 

8. With burner operating, the control 

knob may be turned  counter-
clockwise to desired heating level 
between “LOW,” “MED,” and 
“HIGH.”

TO SHUT DOWN HEATER

1. Shut off the main burner valve, being 

sure to wear a glove for protection. 
Turn the control knob to the “OFF” 
position.

2. Firmly close the natural gas supply 

valve.

TO RESTART HEATER

1. Wait five minutes for heater to cool.
2. Follow steps in TO START HEATER 

section.

TO START HEATER (RA250NGDGD)

1. Follow all of the safety, ventilation 

and installation instructions 
previously noted in this manual.

2. Always be sure to place the heater on 

a stable and level surface while the 
heater is in operation. Be sure that no 
strong winds blow into the ends of 
the heater.

3. SLOWLY open the gas valve.
4. Push in and hold the automatic 

control button (see Figure 4). Push 
ignitor button (see Figure 4). You 
may need to repeat pushing the 
ignitor button several times before 
the pilot will light.

NOTE:

 The gas line may have air in it. 

Press in the automatic control button 
for about 15 seconds for the air to 
pass out of the system. Then push the 
ignitor button once again. Once the 
pilot lights, keep the automatic control 
button pressed in. Release after at least 
15 seconds.
5. If pilot does not light, repeat Step 4.
6. When pilot stays lit, fully open the 

main burner valve by turning the 
handle of the burner valve counter-
clockwise until it stops all the way to 
the ON position.

Dyna-Glo

®

 Delux Natural Gas 

Radiant Heaters

RA100NGDGD and RA250NGDGD

Dyna-Glo Delux Operating Instructions and Parts Manual

Figure 4 – RA250NGDGD Part Identification

Shell

Emitter

Regulator

Base Chamber

Upper Base

Tubing Outlet Assembly

Control Valve Assembly

Lower Base

Tubing Inlet Assembly

Ignitor

Tubing Pilot Assembly

Pilot Assembly

Nozzle Bracket

Main 

Nozzle Flame 

Shield

Insulation Ring

Base Shield

Tip Over Switch
Automatic Control Button

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:00 am - 5:00 pm CST          www.ghpgroupinc.com

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Summary of Contents for RA100NGDGD

Page 1: ...s heater If you need assistance or heater information such as an instruction manual labels etc contact your local manufacturer Consumer Retain this manual for future reference Dyna Glo Delux Natural G...

Page 2: ...ntenance method you use Carbon Monoxide poisoning may lead to death Some people are more affected by Carbon Monoxide than others Early signs of carbon monoxide poisoning resemble the flu with headache...

Page 3: ...ious or fatal injury Assembly MODEL RA100NGDGD 1 Provide natural gas supply system 2 Install plumbing to a low pressure natural gas source to heater The source must be regulated to 1 2 PSI maximum 3 4...

Page 4: ...o the OFF position 2 Firmly close the natural gas supply valve TO RESTART HEATER 1 Wait five minutes for heater to cool 2 Follow steps in TO START HEATER section TO START HEATER RA250NGDGD 1 Follow al...

Page 5: ...k NFPA54 ANSI Z223 1 or the Natural Gas Installation Code CAN CSA B149 1 VENTILATION A three square foot opening of fresh outside air for each 100 000 BTU Hr of heater output must be provided to opera...

Page 6: ...0NGDGD Dyna Glo Delux Operating Instructions and Parts Manual Symptom Possible Cause s Corrective Action Burner fails to light Burner lights but goes out when automatic control valve button is release...

Page 7: ...ll 1 877 447 4768 Please provide following information Model number Serial number if any Part description and number as shown in parts list Figure 6 Repair Parts Illustration for Natural Gas Radiant H...

Page 8: ...Base 5002851 1 14 Control Knob 2101451 1 15 Control Valve 5050651 1 16 Fitting 2304948 2 17 Tubing Inlet Assy 2315524 1 18 Fitting Regulator to Tubing Inlet 2315547 1 19 Regulator 2315555 1 20 Regula...

Page 9: ...3 14 15 16 17 18 19 20 4 5 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 38 39 40 41 For Technical Support or Troubleshooting Call 1 877 447 4768 8 00 am 5 00 pm CST www ghpgroupinc com For Repai...

Page 10: ...5536 1 25 Regulator Connector 2315547 1 26 Inlet Tubing Assy 2315542 1 27 Connector 2315549 1 28 Control Valve 5001423 1 29 Contol Valve Fixing Nut 2305687 1 30 Contol Valve Bracket 2315538 1 31 Ball...

Page 11: ...MAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or cons...

Page 12: ...u can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here Tel...

Reviews: