Figure 13. Conveyor Belt Sub Screen
UV Lamp Settings
The UV Lamp Settings Sub Screen (Figure 14) shows the status of the lamp driver. This includes the current lamp power, voltage,
and amperage, as well as the fan speed of each of the three irradiator fans. Diagnostic test buttons allow the operator to run the
irradiator fans independent of the machine at any set speed. This is helpful for diagnosing whether a fan is operating correctly. The
irradiator fans have tachometers on them, and the program is written to constantly monitor the fan speed. If the fans fall below a
threshold speed, the fans will turn off, along with the UV lamp and conveyor, and a fan error message will appear. The fan that
triggered the error will appear red in the fan status bar.
The user must clear the fan error by depressing the reset button before the machine will be functional. The fan levels must be
above the values shown below to be considered properly working.
These values are 20 % below the fans nominal speed:
•
Low Power : 400 RPM
•
Medium Power: 1500 RPM
•
High Power : 4000 RPM
Figure 14. UV Lamp Sub Screen