21
Dymax SG-200 High-Flow Spray Gun System User Guide
WARNING!
Some Dymax fluids can bond skin together in seconds. It can also irritate skin,
eyes, and mucous membranes. To minimize the risk of bonded skin or irritation, wear protective
gloves and eyewear when working with Dymax fluids and the hand-held spray gun system.
Exposing Dymax adhesives to light causes most Dymax adhesives and fluids to begin curing.
Hence, to prevent unintentional curing during the loading of pail reservoirs, have the reservoir
tank ready to accept the pail reservoir and complete the loading process quickly after opening the
pail reservoir.
Connecting Air to the Ram Pump
1.
Verify that all valves ar
e in the “Off” position before making any connections. See Ram Pump Operator’s
Manual for directions. Ensure the pump is mounted and secure per factory use instructions.
2.
Determine the distance from the factory air supply line to the ram pump location. Cut 3/8-in tubing to
desired length.
3.
Locate the push-
connect “air in” fitting on the bottom of the ram pump manifold and insert tubing.
Connect opposite end of the tubing to the factory air supply using a quick-connect fitting.
4.
Ensure piston is lubricated. Test the ram pump actuation by raising and lowering the ram head (See Ram
Pump Operator’s Manual for directions).
Figure 11. Ram Pump Connections
Air line
–
Connects from Material Pressure
Regulator to manifold
Fluid Line
Material
Regulator