BlueWave® MX-250 Emitter User Guide
10
Product Cleaning and Care
▪
Product cleaning is limited to wiping the product with a damp cloth. Do not soak.
Isopropanol Alcohol or household cleaners may be used for cleaning the product.
▪
Always inspect the quartz window for cleanliness before use. Foreign material can cause
permanent damage to the window. Clean with Isopropanol Alcohol to remove smudges or
foreign material. Damaged or permanently etched windows should be replaced.
▪
Do not use compressed air to removed particle debris inside the emitter as it may damage
the high-speed cooling fan.
Glass Window Replacement
1.
Before starting, disconnect power to the unit.
2.
Lay the emitter on its side with the cover facing upwards. Using a 5/64” hex key, loosen
and fully remove the two screws (Figure 4).
3.
Remove the side cover by lifting from the bottom as shown in Figure 5.
Figure 4. Remove Screws
Figure 5. Remove Side Cover
4.
Slide the damaged glass cover out (Figure 6), taking care not to touch the metallic reflector
surfaces
.
NOTE: If the old window has shattered, be sure to remove all debris before attempting to
install the new glass window.
5.
Unwrap the new window and carefully clean with the enclosed alcohol swab. Holding the
window by its sides, slide into the groove (Figure 7). Take care not to touch the glass with
bare hands, as any residue left on the window can adversely affect the performance of the
unit.