background image

 

 

© 2008-2015 Dymax Corporation.  All rights reserved.  

All trademarks in this guide, except where noted, are the property of, or used under license by Dymax Corporation, U.S.A.

 

Please note that most dispensing and curing system applications are unique.  

Dymax does not warrant the fitness of the product for the intended application.  Any warranty applicable to the product, its application and 

use is strictly limited to that contained in Dymax’s standard Conditions of Sale.  Dymax recommends that any intended application be evaluated and tested by the user to insure that desired performance criteria are 
satisfied.  Dymax is willing to assist users in their performance testing and evaluation by offering equipment trial rental and leasing programs to assist in such testing and evaluations.  Data sheets are available for valve 
controllers or pressure pots upon request.

  

        

        PN40518             MAN003              12/28/2015 

       

Dymax Corporation

 

860.482.1010 | [email protected] 

www.dymax.com 

 

Dymax Oligomers & Coatings

 

860.626.7006 | [email protected] | 

www.dymax-oc.com

 

 

Dymax Asia (H.K.) Limited 

+852.2460.7038 | [email protected] | 

www.dymax.com.cn

 

Dymax Europe GmbH 

+49 (0) 611.962.7900 | [email protected] 

www.dymax.de 

 

Dymax UV Adhesives & Equipment (Shanghai) Co. Ltd.   

     

+86.21.37285759 | [email protected] 

www.dymax.com.cn

 

Dymax Asia Pacific Pte. Ltd. 

+65.6752.2887 | [email protected] | 

www.dymax-ap.com 

Dymax Engineering Adhesives Ireland Ltd. 

+353.1.231 4696 | [email protected] | 

www.dymax.ie

  

Dymax UV Adhesives & Equipment (Shenzhen) Co. Ltd. 

+86.755.83485759 | [email protected] | 

www.dymax.com.cn

 

Dymax Korea LLC

 

+82.2.784.3434 | [email protected] | 

www.dymax.com/kr

 

 

 

 

Summary of Contents for Accu-Cal 50

Page 1: ...CU CAL 50V User Guide Visible Radiometer Instructions for Safe Use Setup and Operation Maintenance Ordering Spare Parts and Accessories ACCU CAL 50V for Flood Lamps PN 40044 ACCU CAL 50V for Spot Lamps PN 40043 ...

Page 2: ...hroughput System designs enable stand alone configuration or integration into your existing assembly line Please note that most dispensing and curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its application and use is strictly limited to that contained in the Dymax standard Conditions of Sal...

Page 3: ...tshinweise 5 Product Overview 6 Description of the ACCU CAL 50V Radiometer 6 Installation 6 Unpacking and Inspecting Your Shipment 6 Parts Included for Spot Configuration 7 Parts Included for Flood Configuration 7 Operation 7 Maintenance 9 Spare Parts and Accessories 10 Spare Parts 10 Specifications 10 Warranty 11 ...

Page 4: ...ace et de faire marcher cette nouveau système de lampe de tache ou cettes composants individuel If you encounter a problem have any questions or would like to help us with your suggestions or recommendations please contact our Technical or Customer Service Departments at 860 482 1010 Trained Dymax professionals are standing by to serve you Si vous rencontrez un problème avait n importe de question...

Page 5: ...important Le plan étais developer pour render au maxime opérateur sécurité et minimiser expositon à ultraviolette Recommander de sécurité Emploi lunettes ou un protéger de visage pour protection de ultraviolet pour protéger vous oeux Chemises à manche long ou manteau de labo sont recommander pour protéger les bras et utilisation de ultraviolette gants opague vais protéger les mains Sicherheitshinw...

Page 6: ...rm environment Under certain circumstances condensation could develop and may cause inaccurate measurement results Allow the device to adjust to room temperature before use Do not use the ACCU CAL 50V radiometer in powerful magnetic electromagnetic or electrostatic fields These disturbances may influence measurement results Installation Unpacking and Inspecting Your Shipment When your radiometer a...

Page 7: ...iometer Parts Included for Flood Configuration ACCU CAL 50V Radiometer ACCU CAL 50V Radiometer User Guide Carrying Case Operation 1 The ACCU CAL 50V Radiometer may be used to measure visible light intensity from flood lamps or spot lamp visible light intensity from the end of a 3 mm 5 mm or 8 mm lightguide For flood lamp use attach the detector to the radiometer as shown in Figure 3 2 For spot lam...

Page 8: ...provided Figure 5 Adapter Installation 4 Attach the Lightguide Adapter to the Spot Lamp Lightguide by inserting the Lightguide into the Lightguide Adapter until it bottoms out Tighten the set screw when the Lightguide is installed 5 Press and release the On Off Key on the Face Plate to turn the Radiometer on and off Figure 6 Attach Lightguide Adapter to Lightguide Step 4 Figure 7 Face Plate ...

Page 9: ... seen by the detector during the measurement Intensity Shows the visible light intensity in mW cm2 at the detector during the measurement Dose Shows the total visible light dose in mJ cm2 at the detector during the measurement Maintenance The ACCU CAL 50V was designed to operate with minimum maintenance Follow the schedule below to assure top unit performance Calibrate the instrument at least annu...

Page 10: ...htguide Adapter 39556 Specifications Property Specification Power Two AA size batteries Display LCD Graphic Display 97x 32 Pixel Display area 0 56 in x 1 41 in 14 3 mm x 35 8 mm Detector Interface 9 Pin MDSM9 socket 4 inputs Measurement Ranges Four modes of operation Auto range within each operating mode Front Panel Control 3 buttons Temperature Operating 5 to 40 C Storage 10 to 50 C Size 5 71 in ...

Page 11: ...of equipment may void your warranty benefits The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment IMPORTANT NOTE DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES EXPRESSED OR IMPLIED DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT WITHOUT WRITTEN AUTHORIZATIO...

Page 12: ...ing equipment trial rental and leasing programs to assist in such testing and evaluations Data sheets are available for valve controllers or pressure pots upon request PN40518 MAN003 12 28 2015 Dymax Corporation 860 482 1010 info dymax com www dymax com Dymax Oligomers Coatings 860 626 7006 info_oc dymax com www dymax oc com Dymax Asia H K Limited 852 2460 7038 dymaxasia dymax com www dymax com cn...

Reviews: