background image

 

Dymax ACCU-CAL™ 50-LED Radiometer User Guide 

Contents 

Introduction .................................................................................................................................................... 4

 

General Safety ................................................................................................................................................................. 5

 

Safety ............................................................................................................................................................................... 5

 

Sécurité ........................................................................................................................................................................... 5

 

Sicherheitshinweise ......................................................................................................................................................... 6

 

Product Overview ........................................................................................................................................... 6

 

Description of the ACCU-CAL™ 50-LED Radiometer ........................................................................................................ 6

 

Installation ...................................................................................................................................................... 7

 

Unpacking and Inspecting Your Shipment ....................................................................................................................... 7

 

Parts Included for Spot & Line array Configuration ......................................................................................................... 8

 

Parts Included for Flood Configuration ........................................................................................................................... 8

 

Operation ....................................................................................................................................................... 9

 

Testing a Flood Lamp System .......................................................................................................................................... 9

 

Testing Spot Lamp Systems ........................................................................................................................................... 10

 

Testing a Line Array System ........................................................................................................................................... 12

 

Testing the BlueWave

®

 QX4

 ......................................................................................................................................... 15

 

Maintenance ................................................................................................................................................. 17

 

Spare Parts and Accessories .......................................................................................................................... 17

 

Spare Parts .................................................................................................................................................................... 17

 

Specifications ................................................................................................................................................ 18

 

 

Summary of Contents for ACCU-CAL 50-LD

Page 1: ...x ACCU CAL 50 LED User Guide LED Radiometer Instructions for Safe Use Setup and Operation Maintenance Ordering Spare Parts and Accessories ACCU CAL 50 LED PN 40519 ACCU CAL 50 LED with Adapter Kit PN 40505 ...

Page 2: ... throughput System designs enable stand alone configuration or integration into your existing assembly line Please note that most dispensing and curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its application and use is strictly limited to that contained in the Dymax standard Conditions of S...

Page 3: ... 50 LED Radiometer 6 Installation 7 Unpacking and Inspecting Your Shipment 7 Parts Included for Spot Line array Configuration 8 Parts Included for Flood Configuration 8 Operation 9 Testing a Flood Lamp System 9 Testing Spot Lamp Systems 10 Testing a Line Array System 12 Testing the BlueWave QX4 15 Maintenance 17 Spare Parts and Accessories 17 Spare Parts 17 Specifications 18 ...

Page 4: ... setting up and operating this instrument and any associated light curing systems If you encounter a problem have any questions or would like to help us with your suggestions or recommendations please contact our Technical or Customer Service Departments at 860 482 1010 Trained Dymax professionals are standing by to serve you Par conséquent nous vous encouragez a lire comprend et suivre tout sécur...

Page 5: ...shinweise Safety The ACCU CAL 50 LED Radiometer is designed to be used in conjunction with Dymax LED curing equipment that is properly set up with components correctly connected and operated in accordance with relevant instructions Safety Recommendations When working with UV or visible light sources use goggles provided or a face shield approved for UV protection to protect your eyes Long sleeved ...

Page 6: ...tquelle wenn das Gerät angeschaltet ist Product Overview Description of the ACCU CAL 50 LED Radiometer The ACCU CAL 50 LED Radiometer is a microprocessor based measurement instrument designed to measure curing energy radiation in the range of 350 450 nm The ACCU CAL 50 LED uses two AA batteries Environmental Considerations Optical measurement instruments are sensitive to extremes in environmental ...

Page 7: ...nd Inspecting Your Shipment When your radiometer arrives inspect the box and immediately notify the shipper of any damage Open the box and check for equipment damage If parts are damaged notify the shipper and submit a claim for the damaged parts Contact Dymax so that new parts can be shipped to you immediately Check that the parts included in your order match those listed below If parts are missi...

Page 8: ...ly Parts Included for Spot Line Array Configuration ACCU CAL 50 LED Radiometer ACCU CAL 50 LED Radiometer User Guide 3 mm 5 mm 8 mm Lightguide Adapters Optic Adapter for the BlueWave QX4 Line Array Adapter Lightguide Simulator PN 38408 2 mm Hex Wrench Spare 2 mm Adapter Screws Parts Included for Flood Configuration ACCU CAL 50 LED Radiometer ACCU CAL 50 LED Radiometer User Guide ...

Page 9: ...il Flood Lamp appears on the top line of the display Figure 5 Figure 4 Attach Detector to Radiometer Figure 5 Flood Source Screen Shown in Peak Intensity Mode 5 Press and release the Mode button to select the operating mode Repeatedly press the Mode button until the mode you desire appears on the second line of the display The different operating modes are Peak Intensity Shows the highest intensit...

Page 10: ...to the lightguide adapter until it bottoms out Tighten the set screw when the lightguide is installed Note Do not over tighten the set screw as damage to the lightguide may occur Figure 8 Attach Lightguide Adapter to Lightguide 7 Press and release the On Off button on the radiometer s face plate to turn the unit on 8 On the radiometer s display the top line displays the light source and the second...

Page 11: ... to select the operating mode Repeatedly press the Mode button until the mode you desire appears on the second line of the display The different operating modes are Peak Intensity Shows the highest intensity in mW cm 2 seen by the detector during the measurement and stores that value in the display Intensity Shows the intensity in mW cm 2 at the detector during the measurement This is a dynamic re...

Page 12: ...meter Figure 11 2 Select the line array adapter Figure 10 Line Array Adapter 3 Install the line array adapter onto the detector face using the two 2 mm screws provided Figure 12 Figure 11 Attach Detector Figure 12 Adapter Installation Note Do not over tighten the set screw as damage to the lightguide may occur ...

Page 13: ...d stores that value in the display Intensity Shows the intensity in mW cm 2 at the detector during the measurement This is a dynamic readout of intensity Dose Shows the total energy dose in mJ cm 2 at the detector during the measurement Note This measurement is time dependent 7 Taking measurements Static readings for general process control when emitter and target are fixed and working distances a...

Page 14: ...adapter tabs to ensure precise engagement Figure 14 Adapter Alignment 2 Keep the sensor and emitter square to each other and activate an exposure cycle of the emitter 3 Take intensity reading after 5 10 seconds to allow for output stabilization 4 To avoid possible damage to the radiometer sensor allow the sensor to cool between measurements and do not expose the sensor to energy emissions for more...

Page 15: ...diometers Figure 15 Attach Detector Figure 16 Attach Optic Adapter to Detector 3 Insert the LED Wand into the Optic Adapter until it bottoms out Tighten the set screw on the top of the Optic Adapter when the LED Wand is installed Note Do not over tighten the set screw as damage to the LED wand may occur Figure 17 Insert LED Wand into Optical Adapter 4 Press and release the On Off button on the rad...

Page 16: ...d 8 mm Spot For use when measuring a BlueWave QX4 Wand with the 8 mm Focus Lens installed Figure 18 Spot Mode Screens Shown in Peak Intensity Mode 7 Press and release the Mode button to select the operating mode The different operating modes are Peak Intensity Shows the highest intensity in mW cm 2 seen by the detector during the measurement and stores that value in the display Intensity Shows the...

Page 17: ...e 19 Battery Compartment Closed Open Keep the detector head s sensing element clean and free of contaminants The detector head may be cleaned with a clean tissue wetted with isopropyl alcohol Spare Parts and Accessories Spare Parts Item Part Number BlueWave QX4 Optic Adapter Upgrade Kit includes optometer calibration update 42218 Adapter Kit Flood to Spot Model includes parts listed below 39554 Li...

Page 18: ...play area 0 56 in x 1 41 in 14 3 mm x 35 8 mm Spectral Range 350 450 nm Detector Interface 9 Pin MDSM9 socket 4 inputs Measurement Ranges Four modes of operation Auto range within each operating mode Front Panel Control 3 buttons Temperature Operating 5 to 40 C Storage 10 to 50 C Size 5 71 in x 2 48 in x 1 18 in 145 mm x 63 mm x 30 mm Weight 0 33 lbs 150 g ...

Page 19: ...pment may void your warranty benefits The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment IMPORTANT NOTE DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES EXPRESSED OR IMPLIED DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT WITHOUT WRITTEN AUTHORIZATION FROM ...

Page 20: ... by offering equipment trial rental and leasing programs to assist in such testing and evaluations Data sheets are available for valve controllers or pressure pots upon request PN40506 MAN002 3 14 2019 Dymax Corporation 1 860 482 1010 info dymax com www dymax com Dymax Oligomers Coatings 1 860 626 7006 info_oc dymax com www dymax oc com Dymax Asia H K Limited 852 2460 7038 dymaxasia dymax com www ...