9
Dymax UVCS 2.0 Light-Curing Conveyor User Guide
CAUTION!
Each Fusion Lamp Assembly has a fine mesh RF Screen covering the Lamp Face. Great
care should be taken during installation and handling of these units to avoid puncturing or damaging
the RF Screen. RF energy can be released if the RF Screen is damaged in any way.
Figure 3. Cable Configuration
Figure 4. Irradiator
5.
Inspect the RF Screen on the bottom of the Irradiator. Make sure there are no rips or tears in the RF
Screen.
NOTE:
Any tears in the RF Screen will result in an RF Interlock failure when the equipment is operated.
6.
Mount the Irradiator(s) into the Conveyor’s Lamp Support (
Figure 5). Take particular care not to
damage the Protective Screen covering the Bulb end of the Irradiators.
Figure 5. Conveyor with Lamp(s) Installed
7.
Locate the RF Detector Mounting Bracket on the opening provided in the Lamp Basket Assembly
(Figure 7). The RF Detector senses microwave leakage through the Rubber Window in the wall of the
Conveyor. Microwave leakage indicates a torn Protective Screen on the bottom of the Irradiator.
NOTE:
The RF Detector Assembly is pre-installed on all new conveyors purchased with Fusion Lamps.
8.
Install the RF Detector
next to the Fusion Irradiators on the Conveyor’s intake side (if not already
installed). Attach the RF D
etector’s
Connector Cord to the RF Detector (Figure 7).