14
Dymax UVCS 2.0 Light-Curing Conveyor User Guide
Maintenance
Belt-Tracking Adjustment
All Dymax UVCS Conveyors are factory adjusted to
provide proper tracking of the Belt. Should further
adjustments become necessary, there are two
knurled Adjustment Knobs located at the input end of
the Conveyor (Figure 16). To adjust tracking, simply
tighten the side to which the Belt is tracking.
NOTE:
Do not over tighten the Belt. This will lead to
accelerated degradation of the Belt. The Belt should
be stoppable with moderate hand pressure.
Figure 16. Belt-Tension Adjustment Knob
Conveyor Belt Replacement
1.
Remove the Pinch Guard from the motor side of the Conveyor by removing the two M4x8 Screws
(Figure 17) on the front side of the Conveyor and the M4x25 Screw (Figure 18) from the motor-drive
side of the Conveyor.
2.
Remove the Pinch Guard from the input side of the Conveyor by removing the three M4x8 Screws
(Figure 19) from both sides.
Figure 17. Two M4x8 Screws
Figure 18. M4x25 Screw
Figure 19. Three M4x8
Screws
3.
Remove all tension from the Belt by fully backing off the Belt-Tension Adjustment Knobs (Figure 16).
4.
Position the Belt Splice to the end of the Conveyor (Figure 20). Remove the Fiberglass Rod that ties
the ends of the Belt together (Figure 21). Remove the Belt.
5.
Run the new Belt around the Conveyor Frame (Figure 22).
6.
Install the Fiberglass Rod through the Belt Loops.