GVL 8301-K

 

GVL 8301-K

11/12

English

99.821.72 1.4/02/16

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Declaration of Conformity

We  declare  under  our  sole  responsibility  that  the 
product  described  under  “Technical  Data”  is  in 
conformity with the following directives:

2014/30/EU, 2014/35/EU

Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek

Dirk Dingfelder

Maik Schmees

Member of the Board 

Authorized signatory, Technical Director

22.02.2016

Only if wind detector or rain detector available:

If the weather automatic is switched on via vent button LT 84-U-W 
(optional), the system will automatically close in case of wind or rain.
The system will not automatically open again, if wind or rain has 
stopped. Opening of the system for ventilation via vent button.
The weather automatic can be switched-off at vent button LT 84-U-W 
(optional), if gap ventilation is required in case of bad weather.
Gap ventilation is not possible in case of bad weather, if no vent 
button LT 84-U-W available.

Operation - Weather automatic

Automatic

on/off

LT 84-U-W

ST OP

ST OP

ST OP

Operation - Day-to-day ventilation

Open:

Close:

Stop:

Ventilation button required.

ST

OP

Connection examples

5

1

3

2

RTR 231

VRS 10

+24V

2

1

3

4

5

6

24 V DC

Window

Drive

P

P

S

LT 84-U-W 

M1

GVL 8301-K

X1

1

2

Mot.b

5

Mot.b

8

Mot.b

1

Mot.a

4

Mot.a

7

Mot.a

3

Fail / 

TMS+

6

Fail / 

TMS+

9

Fail / 

TMS+

8

A

Z

7

–N

6

5

L

4

Az

Zz

3

+G

2

M2

M3

VCD 20x

VRS 10

+24V

2

1

3

4

5

6

2x 24 V DC

Window drives

on one window

P

P

S

LT 84-U-W 

M1

GVL 8301-K

X1

1

2

Mot.b

5

Mot.b

8

Mot.b

1

Mot.a

4

Mot.a

7

Mot.a

3

Fail / 

TMS+

6

Fail / 

TMS+

9

Fail / 

TMS+

8

A

Z

7

–N

6

5

L

4

Az

Zz

3

+G

2

M2

M3

VCD 20x

LT 84-U

LT 84-U

* Connect lead directly when no automatic switch available. In this case the manual operation is out of function.

Ask your local D+H partner for further connection examples.

Automatic

on/off

Automatic

on/off

ST OP

ST OP

Maintenance and cleaning

Inspection  and  maintenance  has  to  be  carried  out 
according  to  D+H  maintenance  notes.  Only  original 
D+H spare parts may be used. Repair is to be carried 
out exclusively by D+H.
Wipe away debris or contamination with a dry, soft 
cloth.
Do not use cleaning agents or solvents.

Summary of Contents for D+H GVL 8301-K

Page 1: ...GVL 8301 K instructions ...

Page 2: ...objects For triggering of 24 V DC drives 1 ventilation group 1Atotal actuating current Expandable with D H accessories Only for indoor mounting WARNING Read all safety warnings instructions illustrations and specifications provided with this product Failure to follow all instructions listed below may result in electric shock fire and or serious injury Save all warnings and instructions for future ...

Page 3: ...st be cut out with side cutting pliers if the window which is to open is within arm s reach fitting heights of the window less than 2 5 m Through this a key operation function will be achieved with closing of the window The window wing will be closing only as long as the vent button is operated In this case automatic control is not permissible e g by room temperature control or wind rain detector ...

Page 4: ...ntrol panel vent button ca 1 2 m above upper edge firm flooring external control 4x 0 8 Ø 4x 0 8 Ø 2x 0 8 Ø 4x 0 8 Ø rain sensor room temperature control Line lenghts and cross sections Cross section mm cable lenght m x total current 80 total current 0 5 A 240 400 640 1 A 120 200 320 m m m type 2x 1 5 mm 2x 2 5 mm 2x 4 mm 230 VAC supply Covering Place enclosed protection cap over supply terminal a...

Page 5: ...RS 10 24V 2 1 3 4 5 6 2x 24 V DC Window drives on one window P P S LT 84 U W M1 GVL 8301 K X1 1 2 Mot b 5 Mot b 8 Mot b 1 Mot a 4 Mot a 7 Mot a 3 Fail TMS 6 Fail TMS 9 Fail TMS 8 A Z 7 N 6 5 L 4 Az Zz 3 G 2 M2 M3 VCD 20x LT 84 U LT 84 U Connect lead directly when no automatic switch available In this case the manual operation is out of function Ask your local D H partner for further connection exa...

Page 6: ...rector 22 02 2016 Only if wind detector or rain detector available If the weather automatic is switched on via vent button LT 84 U W optional the system will automatically close in case of wind or rain The system will not automatically open again if wind or rain has stopped Opening of the system for ventilation via vent button The weather automatic can be switched off at vent button LT 84 U W opti...

Page 7: ...Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk ...