WSD-1 is a digital sensor with on-board firmware. The firmware provides critical functions
including sensor element interface, sensor value processing, calibration scaling, error detection,
power management, and Modbus operation. The firmware also includes a boot loader for in-field
firmware changes.
Boot Loader
WSD-1 firmware may be updated in the field through the RS-485 serial data lines.
Required Equipment
RS-485 to USB (or RS-232) converter.
12 VDC power supply.
Mi-Met Boot Loader PC utility.
Procedure
1. Disconnect WSD-1 from the host equipment.
2. Connect the WSD-1 to the PC with the RS-485 converter.
3. Connect WSD-1 to a 12 VDC power source.
4. Run the Mi-Met Boot Loader Utility. Configure the settings and press “Load.”
5. Watch for program completion.
6. Disconnect and return the WSD-1 to service.