background image

- 6 -

REMOVE

CAM

Fig.

 

E.

Fig.

 

D.

REMOVE

CAM CAP

Fig.

 

F.

M965534 Rev. 1.9 (4/18)

• Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled as 

“Cam” in the illustration. 

Fig. B.

•  Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the 

Stopper should be in the UP position. 

Fig. B, C. 

• Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig. C.

•  Re-attach the Cable to the Drain Body Connection

 (2)

 by threading the Cable Connector 

(1)

 clockwise onto the 

Drain Body Connection 

(2)

 and hand-tighten. 

Fig. A.

• Disconnect the Cable from the Drain by threading the Cable Connector

 (1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled 

as “Cam”  and “Cam Cap” in the illustration. 

Fig. B.

• Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain.

 Fig. D.

• Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig. E.

• The Stopper can now be removed by lifting it out of the Drain. 

Fig. F.

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

     • Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.                                                                       

CABLE ADJUSTMENT PROCEDURE

STOPPER REMOVAL PROCEDURE

Speed Connect

®

 Drain

Troubleshooting Guide

CAM

CAM CAP

Fig.

 

B.

Fig.

 

A.

2

1

RE-ATTACH

DISCONNECT

Fig.

 

C.

DOWN

STOPPER

Summary of Contents for Percy D35105870

Page 1: ...mm 2 1 4 DIA 57 mm 7 8 DIA 22 mm 1 1 2 MAX 38 mm CROSS HANDLE 10 1 2 MAX 267 mm 1 1 4 O D 32 mm 2 MAX 51 mm 1 1 2 37 mm CYLINDER HANDLE 2 1 2 63 mm NOTE MOUNTING HOLES ARE 1 3 8 DIA 35 mm CONNECTIONS 1 2 IPS FLEXIBLE SUPPLIES 3 8 O D BULL NOSE RISERS 3 77 mm TRI SPOKE HANDLE In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents...

Page 2: ...ALVE BODY marked Hot Red Dot is installed in the left Mtg hole VALVE BODY marked Cold Blue Dot in the right when facingfront of fitting Maximum mounting surface thickness is 1 3 4 44mm Install STOP RING 6 onto VALVE BODY 2 Thread FLANGE 7 onto VALVE BODY 2 until tight aganist the STOP RING 6 Align VALVE BODY 2 and from below tighten LOCKNUT 1 to secure VALVE BODY 2 INSTALL HANDELS Install SEAL 8 i...

Page 3: ... GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 mustface towards the rear of the SINK Fig B From under side of SINK install RUBBER CONE WASHER 3 PLASTIC WASHER 2 and LOCKNUT 1 onto DRAIN BODY 4 Note The CABLE ATTACHMENT POINT 5 must face towards the rear of the SINK Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET...

Page 4: ...uctions NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to inlet of left...

Page 5: ...al and retains water in Sink If DRAIN STOPPER 6 does not seal properly please refer to Troubleshooting section in these instructions Push POP UP KNOB 5 down and check all drain connections and P trap for leaks Tighten if necessary TO CLEAN AERATOR AERATOR 3 may accumulate dirt causing distorted and reduced water flow Remove AERATOR 3 and rinse clean Replace AERATOR 3 and operate handles several ti...

Page 6: ...rea on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sin...

Page 7: ...USTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate Sto...

Page 8: ...ON H960741 191 1 2 SIDE VALVE COUNTER CLOCKWISE ON H960104 191 1 2 CARTRIDGE COUNTER CLOCKWISE ON M964630 YYY0A CYLINDER HANDLE ASSEMBLEY M964629 YYY0A CROSS HANDLE ASSEMBLEY M970437 YYY0A TRI SPOKE HANDLE ASSEMBLEY H960279 191 MOUNTING KIT M965534 Rev 1 9 4 18 Percy Widespread Lavatory Faucets MODEL NUMBERS Tri Spoke Handle D35105870 Cross Handle D35105840 D35105840RB Cylinder Handle D35105800 D3...

Reviews: