- 4 -
M965710 Rev. 1.0 (5/17)
9
10
11
ATTACH CABLE CONNECTOR
CHECK OPERATION OF POP-UP
MAKE WATER SUPPLY AND WASTE CONNECTIONS
• Thread CABLE CONNECTOR
(1)
clockwise
onto DRAIN BODY CONNECTION
(2)
and
hand tighten.
Fig. A.
Your new POP-UP DRAIN installation is
now complete.
Fig. B.
Note: Tailpeice on pop-up drain is
1-1/4" O.D. (32mm) Fig. B.
• Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the
“troubleshooting section” of these instructions.
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED
AND MUST BE PURCHASED SEPARATELY.
• Connect water supply to VALVE BODIES
(1,1A)
with 1/2" IPS FLEXIBLE
SUPPLIES
(2)
or 3/8" O.D. BULL-NOSE RISERS
(3)
. Use
adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
• Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
Fig.
A.
2
1
1-1/4" O.D.
(32mm)
Fig.
A.
Fig.
B.
2
HOT
COLD
FERRULE
COMPRESSION
NUT
COUPLING
NUT
FLEXIBLE
SUPPLIES
3/8" (6mm) O.D.
BULL-NOSE
RISERS
1/2" (13mm) PIPE
THREAD
3/8" (6mm) COMPRESSION
CONNECTION
2
3
1A
1