background image

- 4 -

M965710 Rev. 1.0 (5/17)

9

10

11

ATTACH CABLE CONNECTOR

CHECK OPERATION OF POP-UP

MAKE WATER SUPPLY AND WASTE CONNECTIONS

•  Thread CABLE CONNECTOR

 (1)

 clockwise 

onto DRAIN BODY CONNECTION 

(2)

 and 

hand tighten. 

Fig. A.

Your new POP-UP DRAIN installation is
now complete. 

Fig. B.

Note:  Tailpeice on pop-up drain is  

1-1/4" O.D. (32mm) Fig. B.

•  Operate LIFT KNOB

 (1)

 to verify that STOPPER

 (2)

 opens and closes.

Note:  If STOPPER (2) does not open and close properly then refer to the 

“troubleshooting section” of these instructions.

NOTE:  FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED 

AND MUST BE PURCHASED SEPARATELY.

•  Connect water supply to VALVE BODIES

 (1,1A) 

with 1/2" IPS FLEXIBLE 

SUPPLIES

 (2)

 or 3/8" O.D. BULL-NOSE RISERS

 (3)

. Use 

adjustable wrench to tighten connections. Do not over tighten. 
Be careful not to kink copper supply when bending. Use tubing 
cutter to cut to proper length.

•  Connect HOT water supply to inlet of left SHANK and COLD 

water supply to right SHANK using sealant, appropriate 
connectors, and COUPLING NUTS.

Fig.

 

A.

2

1

1-1/4" O.D.

(32mm)

Fig.

 

A.

Fig.

 

B.

2

HOT

COLD

FERRULE

COMPRESSION

NUT

COUPLING

NUT

FLEXIBLE

SUPPLIES

3/8" (6mm) O.D.

BULL-NOSE

RISERS

1/2" (13mm) PIPE

THREAD

 

 

3/8" (6mm) COMPRESSION

CONNECTION

2

3

1A

1

Summary of Contents for Percy D3510584C

Page 1: ...1 4 57 mm 2 1 4 DIA 57 mm 7 8 DIA 22 mm 1 1 2 MAX 38 mm CROSS HANDLE 10 1 2 MAX 267 mm 1 1 4 O D 32 mm 2 MAX 51 mm 1 1 2 37 mm LEVER HANDLE 2 1 2 63 mm NOTE MOUNTING HOLES ARE 1 3 8 DIA 35 mm CONNECTIONS 1 2 IPS FLEXIBLE SUPPLIES 3 8 O D BULL NOSE RISERS In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States...

Page 2: ...urface Note VALVE BODY marked Hot Red Dot is installed in the left Mtg hole VALVE BODY marked Cold Blue Dot in the right when facingfront of fitting Maximum mounting surface thickness is 1 3 4 44mm Install STOP RING 6 onto VALVE BODY 2 Thread FLANGE 7 onto VALVE BODY 2 until tight aganist the STOP RING 6 Align VALVE BODY 2 and from below tighten LOCKNUT 1 to secure VALVE BODY 2 INSTALL HANDELS Ins...

Page 3: ... GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 mustface towards the rear of the SINK Fig B From under side of SINK install RUBBER CONE WASHER 3 PLASTIC WASHER 2 and LOCKNUT 1 onto DRAIN BODY 4 Note The CABLE ATTACHMENT POINT 5 must face towards the rear of the SINK Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET...

Page 4: ...uctions NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to inlet of left...

Page 5: ...al and retains water in Sink If DRAIN STOPPER 6 does not seal properly please refer to Troubleshooting section in these instructions Push POP UP KNOB 5 down and check all drain connections and P trap for leaks Tighten if necessary TO CLEAN AERATOR AERATOR 3 may accumulate dirt causing distorted and reduced water flow Remove AERATOR 3 and rinse clean Replace AERATOR 3 and operate handles several ti...

Page 6: ...rea on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sin...

Page 7: ...USTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate Sto...

Page 8: ...DGE CLOCKWISE ON H960742 191 1 2 SIDE VALVE CLOCKWISE ON H960741 191 1 2 SIDE VALVE COUNTER CLOCKWISE ON H960104 191 1 2 CARTRIDGE COUNTER CLOCKWISE ON M964630 YYY0A LEVER HANDLE ASSEMBLEY M964629 YYY0A CROSS HANDLE ASSEMBLEY H960279 191 MOUNTING KIT M965710 Rev 1 0 5 17 Replace the YYY with appropriate finish code POLISHED CHROME 100 BRUSHED NICKEL 144 MODEL NUMBERS Cross Handle D3510584C Lever H...

Reviews: