- 2 -
M965543 Rev. 1.6 (5/17)
1
2
TRIM INSTALLATION
TEMPERATURE CALIBRATION
• Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
• Check that arrow marking
B
points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to
the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with| arrow
“B”
pointing upwards.
• The maximum mixed water temperature is set at 109˚ F (43° C) at the factory. This setting can be changed if desired.
• Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Re-install it at the desired notch as indicated in the
diagram to limit the maximum mixed water temperature to 104˚F or 112˚F.
• For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100˚F. Check that arrow
marking
A
on the KNOB MOUNT still points upward after adjusting the thermostat to 100˚F. If not, pull out the RED LOCKING
DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directlyin front of the valve.
• Reinstall the KNOB MOUNT so that the arrow marking
A
points upwards.
• Reinstall RED LOCKING DEVICE.
KNOB
MOUNT
ARROW
"A"
BLACK
CLAMP
ARROW
"B"
RED LOCKING
DEVICE
SECURING
RING
TEMPERATURE
LIMIT STOP
104 °F
(40 °C)
109 °F
(43 °C)
112 °F
(44.4 °C)
2
1
3
4
THREADED
MOUNTING HOLES
3
• Push CAP
(1)
over the O-RING SEAL
(2)
.
• Align mounting holes in ESCUTCHEON
(3)
with threaded mounting
holes in valve body.
• Secure ESCUTCHEON
(3)
with SCREWS
(4)
.
• Push DIAL PLATE
(5)
onto CAP
(2)
.