background image

- 8 - 

Technical Support 

 

If you have questions about this product, or if you experience difficulties during the installation, 
contact DX Engineering at (330) 572-3200.  You can also e-mail us at: 

 
 

[email protected]

 

 
 

For best service, please take a few minutes to review this manual before you call. 

 

Manual Updates 

 
Every effort is made to supply the latest manual revision with each product. Occasionally a manual 
will be updated between the time your DX Engineering product is shipped and when you receive it. 
Please check the DX Engineering web site (

www.dxengineering.com

) for the latest revision manual.

 

 

Warranty 

All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a 
period of one (1) year from date of shipment. DX Engineering’s sole obligation under these warranties shall be to issue 
credit, repair or replace any item or part thereof which is proved to be other than as warranted; no allowance shall be 
made for any labor charges of Buyer for replacement of parts, adjustment or repairs, or any other work, unless such 
charges are authorized in advance by DX Engineering. 

If DX Engineering’s products are claimed to be defective in material or workmanship, DX Engineering shall, upon 
prompt notice thereof, issue shipping instructions for return to DX Engineering (transportation-charges prepaid by 
Buyer). Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing. 
The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or 
neglect, damaged by accident, rendered defective by reason of improper installation, damaged from severe weather 
including floods, or abnormal environmental conditions such as prolonged exposure to corrosives or power surges, or 
by the performance of repairs or alterations outside of our plant, and shall not apply to any goods or parts thereof 
furnished by Buyer or acquired from others at Buyer’s specifications. In addition, DX Engineering’s warranties do not 
extend to other equipment and parts manufactured by others except to the extent of the original manufacturer’s warranty 
to DX Engineering. 

The obligations under the foregoing warranties are limited to the precise terms thereof. These warranties provide 
exclusive remedies, expressly in lieu of all other remedies including claims for special or consequential damages. 
SELLER NEITHER MAKES NOR ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHER 
EXPRESS, STATUTORY, OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS, 
AND NO PERSON IS AUTHORIZED TO ASSUME FOR DX ENGINEERING ANY OBLIGATION OR 
LIABILITY NOT STRICTLY IN ACCORDANCE WITH THE FOREGOING. 
 
©DX Engineering 2017 
 
DX Engineering

®

, DXE

®

, DX Engineering, Inc.

 ®

, Hot Rodz

®

, Maxi-Core

®

, DX Engineering THUNDERBOLT

®

, DX 

Engineering Yagi Mechanical

®

, EZ-BUILD

®

, TELREX

®

, Gorilla Grip

®

 Stainless Steel Boom Clamps, Butternut

®

SkyHawk™, SkyLark™, SecureMount™, OMNI-

TILT

™ are trademarks of PDS Electronics, Inc. No license to use or 

reproduce any of these trademarks or other trademarks is given or implied. All other brands and product names are the 
trademarks of their respective owners. 

 

Specifications subject to change without notice.

 

 

Summary of Contents for DXE-RPA-2

Page 1: ...er DXE RPA 2 DXE RPA 2 INS Rev 0 U S Patent No 7 319 435 DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E...

Page 2: ...RG5000HD PM Receiver Guard Plug in Module While many other common preamplifiers suffer from harmonic distortion the DXE RPA 2 low noise preamplifier features an advanced push pull design that eliminat...

Page 3: ...RPA 2 Receive Preamplifier Input and Output Connectors female BNC and F Frequency Range 300 kHz to 35 MHz Gain 16 dB 1 5 dB over entire frequency range Output Third Order Intercept 43 dBm Noise Figure...

Page 4: ...line losses so the preamplifier can normally be used at the radio Another common misconception is that mounting the preamplifier at the antenna feedpoint reduces feedline noise pickup The location of...

Page 5: ...is connected to positive and has an inline 1A fuse When power is applied to the RPA 2 the green LED will illuminate A standard 2 1 mm power connector with center positive and 13 8 Vdc supply may be u...

Page 6: ...cannot be extended to the antenna feedline In other words when the RPA 2 is powered on the coax any active devices used on the ANTENNA INPUT side of the preamplifier will require separate power conne...

Page 7: ...of Broadcasters NAB handbook or other reliable sources Optional Plug in Module Descriptions and Specifications 75 to 50 ohm Impedance Transformer Plug in Module DXE IT PM A perfect match for changing...

Page 8: ...not extend to any products or parts thereof which have been subjected to any misuse or neglect damaged by accident rendered defective by reason of improper installation damaged from severe weather inc...

Reviews: