- 4 -
D. Squeeze the tool to remove the coaxial cable. There will be 2 cuts made giving you two 1/4” cuts as
shown below. Pull the cut parts off of the coaxial cable.
E. Fold the braid back onto the outer jacket.
NOTE: For Quad Shield: Fold back the outer braid then score and remove
the outer foil in that same area. Then fold back the inner braid on top of
the outer braid. Smooth the two folded braids together.
F. Insert the prepared Coaxial Cable fully into the F Connector as shown.
Ensure the center dielectric is
flush to the inside lip and the center conductor is slightly sticking out the end is as shown.
G. Place the compression connector with coaxial cable into the
DXE-SNS-CT1
Compression tool as shown.
H. Fully squeeze the
DXE-SNS-CT1
Compression Tool handles together to completely compress the
compression
connector as shown.
I. Remove completed coaxial cable assembly from
DXE-SNS-CT1
Compression Tool.