Introduction 

 

This manual will explain the preparation of RG-6, flooded or RG-6 Dual or Quad Shield, 75 ohm coaxial 
cable and the installation of compression connectors using the RG-6 Coaxial Cable Prep Tools supplied by 
DX Engineering. These tools were specifically selected to make the task of preparing RG-6 coaxial cable 
easy, fast and safer then older methods. The RG-6 Coaxial Cable Prep Tool Kit includes: 
 

1

 - Custom Made Case

 with custom pre-cut High Density Foam 

1 - 

CNL-911

 Cable Cutter 

1 - 

DXE-SNS-CT1

 Compression F Connector Tool 

1 - 

DXE-CPT-659

 F6 Coax Prep Tool w/Spare Blade 

1 - 

DXE-CIT-1

 F Connector Tightening Tool 

1-  

DXE-EX6XL-25 

1 package of 25 Compression Type F Conne

ctors 

 

 

General Information 

 

The 

DXE-UT-KITF DX Engineering RG-6 Coaxial Cable Preparation Tool Kit

 provides all the tools 

you need in one convenient custom made case to prepare RG-6 coaxial cable using compression type F 
connectors. These tools will also work with most popular compression connectors other than described here. 
 
DX Engineering offers two types of RG-6 coaxial cable: 
 

DXE-F-1000

 sold in a 1000 spool or 

DXE-F6-CTL

 sold by the foot is a high quality 75 ohm 

‘flooded’ 

coaxial cable ideal for amateur radio receive systems. Flooded-style feedlines have the distinct advantage of 
automatically sealing small incidental cuts or lacerations on the jacket. Flooding also prevents shield 
contamination and allows the coaxial cable to be direct-buried. This low-loss cable features dual shields and 
an 85% velocity factor. The waterproof polyethylene jacket is perfectly suited for direct bury, in conduit or 
above ground applications. 
 

DXE-RG6UQ-1000

 sold in a 1000 foot spool or 

DXE-RG6UQ-CTL sold by the foot. 

DX Engineering 

RG-6UQ 75-ohm Quad-Shield Coaxial Cable reduces losses and provides greater protection against 
electromagnetic interference. RG-6UQ cable is ideal for many applications, such as active or passive HF 
Amateur Radio and SWL receive antenna arrays and systems, LW and MW magnetic loop antennas, 
Beverage antennas, over-the-air TV, AM and FM broadcast reception, CATV systems, video distribution and 
satellite radio installations like Sirius/XM. RG-6UQ - RG-6 quad shield cable has gas-injected polyethylene 
foam dielectric for the lowest loss and maximum moisture resistance. With an 18 AWG copper-clad steel 
center conductor it is extremely strong and durable. Two foil shields plus two high-density aluminum braids 
provide ultimate four-layer RF shielding and the UV protected black jacket is made with a tough, but very 
flexible, PVC. The nominal impedance of RG-6UQ cable is 75 ohms, and it has a nominal Velocity Factor of 
82%.

 

 
 
DXE-EX6XL-25 (25 per package) Compression

 Coaxial Connectors are 

environmentally sealed CATV F-Type coax connectors built and designed for harsh 
environments. They have a unique 360 degree radial compression system that offers the 
signal leakage protection required for high performance receive systems. 
Dielectric Grease is recommended to be used on F6 Connectors exposed to the outside 
environment.  
 
 

Summary of Contents for CNL-911

Page 1: ...Tools Kit DXE UT KITF DXE UT KITF INS Revision 1 DX Engineering 2020 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Technical Support and International 330 572 3200 Fax 330 572 3279 E ma...

Page 2: ...ble to be direct buried This low loss cable features dual shields and an 85 velocity factor The waterproof polyethylene jacket is perfectly suited for direct bury in conduit or above ground applicatio...

Page 3: ...s will stop the adverse effects of water vapor and water ingress Avoiding direct application on mating surfaces of connector center pins dielectric grease is safe to use in the air spaces and threads...

Page 4: ...outer braid Smooth the two folded braids together F Insert the prepared Coaxial Cable fully into the F Connector as shown Ensure the center dielectric is flush to the inside lip and the center conduc...

Page 5: ...to remove an F Connector from your unit Weatherproofing Over the years many different methods have been used to weatherproof coaxial cable connections Some worked some did not Once water or condensati...

Page 6: ...n this example a 4 length of the 3M Temflex 2155 Rubber Splicing Tape was used to weatherproof the F Connector that is installed on a unit B The 3M Temflex 2155 Rubber Splicing Tape has a protective b...

Page 7: ...l Videos DX Engineering has a number of instructional videos that you can view on line that show products used in this guide as well as other informative videos You can view the videos at the DX Engin...

Page 8: ...or by the performance of repairs or alterations outside of our plant and shall not apply to any goods or parts thereof furnished by Buyer or acquired from others at Buyer s specifications In addition...

Reviews: