background image

Product User Guide

Summary of Contents for WTDL-RX

Page 1: ...WTDL RX Wireless Transceiver WTDL RX Product User Guide Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ...Product User Guide ...

Page 3: ...ment with temperatures from 20 C to 85 C and a humidity range of 0 to 95 RH non condensing The WTDL RX is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green LED will blink when communicating with other Dwyer WTDL devices Installation Guide Installing the Software Insert the D...

Page 4: ...r than 700 feet indoors or 2500 feet outdoors or there are walls obstacles corners that need to be maneuvered around set up additional WTDL RXs as needed Step 3 Verify that the data loggers are in wireless transmission mode See Channel Programming steps above Step 4 On a Windows PC launch the DL700 software program All active data loggers will be listed in the software showing that the device s ar...

Page 5: ... 12 Channel 13 Channel 14 Channel 15 Channel 16 Channel 17 Channel 18 Channel 19 Channel 20 Channel 21 Channel 22 Channel 23 Channel 24 Channel 25 Channel 26 not supported Follow the instructions below to configure the channel settings for Dwyer WTDL Data Loggers WTDL RX To program the channel on an WTDL RX first unplug the WTDL RX Use a Phillips head screwdriver to unscrew the enclosure The dip s...

Page 6: ...eless performance both the WTDL RX and the Dwyer WTDL Data Loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to accommodate either a wall mount or a desk mount ...

Page 7: ... CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Under Industry Canada regulations this radio transmitter may...

Page 8: ... ID OA3MRF24J40MC IC 7693A 24J40MC CE ETSI 300 328 EU R TTE Transmission Distance To other WTDL RX s 2 500 max outdoors line of sight unobstructed 700 max indoors typical urban environment Transmission Distance To data loggers 2 000 max outdoors line of sight unobstructed 500 max indoors typical urban Maximum number of connected data loggers 64 Sensitivity 95dBm Typical Frequency 2 405GHz 2 475GHz...

Reviews: