Dwyer Instruments W.E. Anderson WE35 Series Specifications-Installation And Operating Instructions Download Page 1

Series WE35 3-Way NPT Brass Ball Valve

Specifications - Installation and Operating Instructions

Bulletin V-WE35

The 

Series WE35 3-Way NPT Brass Ball Valve

 incorporates a full port 3-way brass 

ball valve for great flow rates with minimal pressure drop. The valve features a blowout 

proof stem for added safety, reinforced PTFE seats and seals for longer life, and a 

brass ball for better performance. Actuators are direct mounted creating a compact 

assembly for tight spaces.

The  Series  WE35  can  be  configured  with  either  an  electric  or  pneumatic  actuator. 

Electric actuators are available in weatherproof or explosion-proof, a variety of supply 

voltages,  and  two-position  or  modulating  control.  Two-position  actuators  use  the 

supply voltage to drive the valve open or closed, while the modulating actuator accepts 

a 4-20 mA input for valve positioning. Actuators feature thermal overload protection 

and permanently lubricated gear train.

The  pneumatic  double  acting  actuator  uses  an  air  supply  to  drive  the  valve  open 

and closed. The actuator has two supply ports, with one driving the valve open and 

the  other  driving  the  valve  closed.  Spring  return  pneumatic  actuators  use  the  air 

supply to open the valve and internally loaded springs return the valve to the closed 

position. Also available is the SN solenoid valve to electrically switch the air supply 

pressure between the air supply ports for opening and closing the valve. Actuators 

are constructed of anodized and epoxy coated aluminum for years of corrosion free 

service.

SPECIFICATIONS

VALVE

Service: 

Compatible liquids and gases.

Body: 

3-way.

Line Sizes: 

1/2 to 2˝.

End Connections: 

Female NPT.

Pressure Limits: 

600 psi (41 bar) WOG.

Wetted Materials: 

Body, ball, and stem: 

Brass; Seat, seal, and packing: PTFE.

Temperature Limits: 

-20 to 425°F (-30 

to 220°C).

Other Materials: 

O-ring: NBR; Handle, 

stem nut, ferrule: SS; Handle Sleeve: 

Vinyl; Body and cap: Nickle plated.

ACTUATORS

Pneumatic “DA” and “SR” Series

Type: 

DA series is a double acting and 

SR series is a spring return (rack and 

pinion).

Normal Supply Pressure: 

DA: 40 to 115 

psi (2.7 to 7.9 bar); SR: 80 psi (5.5 bar).

Maximum Supply Pressure: 

120 psi 

(8.6 bar).

Air Connections:

 DA02 to DA03: 1/4˝  

female NPT; SR02 to SR04: 1/4” female 

NPT.

Housing Material:

 Anodized aluminum 

body and epoxy coated aluminum end 

caps.

Temperature Limits: 

-40 to 176°F (-40 

to 80°C).

Accessory Mounting: 

NAMUR 

standard.

Electric “TD” and “MD” Series

Power Requirements: 

110 VAC, 220 

VAC, 24 VAC, or 24 VDC (MD models 

not available in 24 VDC).

Power Consumption:

 See instruction 

manual.

Cycle Time (per 90°): 

TD01: 4 s; MD01: 

10 s; TD02: 20 s).

Duty Rating:

 85%.

Enclosure Rating:

 NEMA 4X (IP67).

Housing Material: 

Powder coated 

aluminum.

Temperature Limits: 

-22 to 140°F (-30 

to 60°C).

Electrical Connection: 

1/2˝ female NPT.

Modulating Input: 

4-20 mA.

Standard Features: 

Manual override, 

position indicator, and TD models come 

with two limit switches.

Electric “TI” and “MI” Series

Power Requirements: 

110 VAC, 220 

VAC, 24 VAC, 24 VDC.

Power Consumption: 

See instruction 

manual.

Cycle Time (per 90°): 

See instruction 

manual.

Duty Rating: 

See instruction manual.

Enclosure Rating: 

NEMA 7, designed 

to meet hazardous locations: Class I, 

Group C & D; Class II, Group E, F & G; 

Division I & II.

Housing Material:

 Powder coated 

aluminum.

Temperature Limits: 

-40 to 140°F (-40 

to 60°C).

Electrical Connection: 

1/2˝ female NPT.

Modulating Input: 

4-20 mA.

Standard Features: 

Position indicator 

and two limit switches.

WE35-DHD00-T1

WE35-DDA02-L1

WE35-DDA02-T3-NN05

WE35-DDA02-T1-AA01

WE35-DTD01-T3-A

DWYER INSTRUMENTS, INC.

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Phone: 219-879-8000
Fax: 219-872-9057

www.dwyer-inst.com
e-mail: [email protected]

Summary of Contents for W.E. Anderson WE35 Series

Page 1: ...s Body ball and stem Brass Seat seal and packing PTFE Temperature Limits 20 to 425 F 30 to 220 C Other Materials O ring NBR Handle stem nut ferrule SS Handle Sleeve Vinyl Body and cap Nickle plated ACTUATORS Pneumatic DA and SR Series Type DA series is a double acting and SR series is a spring return rack and pinion Normal Supply Pressure DA 40 to 115 psi 2 7 to 7 9 bar SR 80 psi 5 5 bar Maximum S...

Page 2: ... ESR03 T2 WE35 FSR03 T2 WE35 GSR03 T2 WE35 HSR04 T2 WE35 CTD01 T2 A WE35 DTD01 T2 A WE35 ETD01 T2 A WE35 FTD01 T2 A WE35 GTD01 T2 A WE35 HTD02 T2 A WE35 CMD01 T2 A WE35 DMD01 T2 A WE35 EMD01 T2 A WE35 FMD01 T2 A WE35 GMD01 T2 A WE35 HMD01 T2 A MODEL CHART Model Size Ø A in mm L in mm W in mm H in mm Ø D1 in mm Ø D2 in mm ISO ØS in mm Ra in mm Rb in mm PORT M1 Torque in lb CV gal min WE35 CHD00 T1 ...

Page 3: ...7 mm 4 101 mm 4 5 8 117 mm 10 1 2 268 mm 2 1 8 55 mm 8 1 2 216 mm 4 1 4 109 mm 4 7 8 124 mm 9 1 2 242 mm 2 1 4 58 mm 9 3 8 237 mm 4 3 4 122 mm 5 7 8 148 mm 10 7 8 275 mm 2 1 2 64 mm ELECTRIC ACTUATOR NPT 1 2 3 4 1 1 1 4 1 1 2 2 B C D E F 6 1 2 167 mm 5 1 4 133 mm 3 76 mm 6 1 8 154 mm 2 3 4 68 mm 10 1 8 257 mm 9 3 8 239 mm 3 3 8 86 mm 8 1 2 217 mm 5 126 mm 8 1 2 216 mm 9 3 8 239 mm 3 7 8 99 mm 8 1 ...

Page 4: ...ody 4 Remove the pinion through the bottom of the actuator The actuator is now completely disassembled WARNING Be sure the actuator surfaces are free of debris and scratches before reassembling 1 Apply a light film of grease to all O rings and the pinion before replacing 2 Put the pinion 2 back through the actuator with the flats of the pinion shaft running parallel with the body 3 When reassembli...

Page 5: ... ring O ring Guide ring Spring assembly O ring Left end cap Right end cap End cap bolt O ring Gasket Nut Adjusting bolt Extruded aluminum alloy Stainless steel Fluorine silicon rubber Nylon46 Stainless steel Nylon46 Nylon46 Fluorine silicon rubber Nylon46 Stainless steel Stainless steel PPPP 30 GF PPPP 30 GF PPPP 30 GF Casting aluminum alloy Nylon46 Fluorine silicon rubber Fluorine carbon composit...

Page 6: ...ng pad if it is ISO5211 compliant 8 Cycle the unit several times and check the open and closed positions of the valve Cams are pre adjusted at the factory due to the variety of valve designs and types however slight adjustments might be required 9 Replace cover and tighten screws To Set The Open Position 1 Cycle the valve to the open position by applying power to terminals The top cam and switch c...

Page 7: ...HREE CLOSES THE VALVE CW ROTATION TERMINALS 4 5 ARE FOR LIGHT INDICATION WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THE OPEN POSITION GROUND SCREW OPTIONAL BRAKE LIGHTS FOR REMOTE POSITION INDICATION OPTIONAL EQUIPMENT FIELD WIRING Wiring Diagrams for TI01 D to TI06 D 24 VDC DC MOTOR CA M CA M SW 1 SW 2 DC VOLTAGE SPDT SWITCH SHOWN FOR ILLUSTRATION ONLY REVERSING RELAY SUPPLIED BY CUSTOMER FIELD W...

Page 8: ...W IS FAIL IN LAST POSITION UPON LOSS OF SIGNAL SW 3 CLOSE SW 4 OPEN AUXILIARY SWITCHES OPTIONAL OPTIONAL EQUIPMENT FIELD WIRING Wiring Diagrams for MI01 D to MI06 D 24 VDC J1 J2 4 20mA POSITIONER PSC MOTOR CAPACITOR SW 1 CLOSE SW 2 OPEN BRAKE OPTIONAL 1PH 60HZ POWER SUPPLY 4 20mA CONTROL SIGNAL 0 10VDC or 0 5VDC CONTROL SIGNAL REMOVE JP2 JP3 JP4 1K OHM FEEDBACK POTENTIOMETER FIELD WIRING N HOT NOT...

Page 9: ...itions It is not recommended to subject the unit to repeated stall conditions Explosion Proof Electric Actuators 1 DO NOT under any circumstances remove the cover of the actuator while in a hazardous location Removal of the cover while in a hazardous location could cause ignition of hazardous atmospheres 2 DO NOT under any circumstances use an explosion proof electric actuator in a hazardous locat...

Page 10: ...25 0 4 100 24 VDC 2 5 s 25 0 4 100 TI02 and MI01 MI02 Voltage Cycle Time Two Position Cycle Time Modulating Duty Cycle Two Position Duty Cycle Modulating Full Load AMP Draw Torque in lb 110 VAC 5 s 10 s 25 75 0 38 200 220 VAC 5 s 10 s 25 75 0 18 200 24 VAC 5 s 5 s 25 75 0 7 200 24 VDC 5 s 5 s 25 75 0 7 200 TI03 and MI03 Voltage Cycle Time Two Position Cycle Time Modulating Duty Cycle Two Position ...

Page 11: ...______________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ ___________________...

Page 12: ..._______________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________...

Reviews: