19
Analog Value – YTD Max Power
Supported Units:
Kilojoule (17), Megajoule (126), Gigajoule (522)*, Btus (20), Kilo-btus (147), Watt-
hours (18), Kilowatt-hours (19), Megawatt-hours (146), Ton-hours (22)
*Non-Standard BACnet unit
Analog Value – YTD Min Power
Supported Units:
Kilojoule (17), Megajoule (126), Gigajoule (522)*, Btus (20), Kilo-btus (147), Watt-
hours (18), Kilowatt-hours (19), Megawatt-hours (146), Ton-hours (22)
*Non-Standard BACnet unit
Analog Value – MTD Max Power
Supported Units:
Kilojoule (17), Megajoule (126), Gigajoule (522)*, Btus (20), Kilo-btus (147), Watt-
hours (18), Kilowatt-hours (19), Megawatt-hours (146), Ton-hours (22)
*Non-Standard BACnet unit
Analog Value – MTD Min Power
Supported Units:
Kilojoule (17), Megajoule (126), Gigajoule (522)*, Btus (20), Kilo-btus (147), Watt-
hours (18), Kilowatt-hours (19), Megawatt-hours (146), Ton-hours (22)
*Non-Standard BACnet unit
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Present Value
Status Flags
Event State
Reliability
Out of Service
Units
Property List
AV9
"YTD Max Power"
ANALOG_VALUE (2)
Current reading
0
Normal (0)
NO_FAULT_DETECTED (0)
FALSE (0)
Kilojoule (17)
BACnetObjectIdentifier
CharacterString
BACnetObjectType
Real
BACnetStatusFlags
BACnetEventState
BACnetReliability
Boolean
BACnetEngineeringUnits
BACnetARRAY[N] of BACnetPropertyIdentifier
Read
Read
Read
Read
Read
Read
Read
Read/Write
Read/Write
Read
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Present Value
Status Flags
Event State
Reliability
Out of Service
Units
Property List
AV10
"YTD Min Power"
ANALOG_VALUE (2)
Current reading
0
Normal (0)
NO_FAULT_DETECTED (0)
FALSE (0)
Kilojoule (17)
BACnetObjectIdentifier
CharacterString
BACnetObjectType
Real
BACnetStatusFlags
BACnetEventState
BACnetReliability
Boolean
BACnetEngineeringUnits
BACnetARRAY[N] of BACnetPropertyIdentifier
Read
Read
Read
Read
Read
Read
Read
Read/Write
Read/Write
Read
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Present Value
Status Flags
Event State
Reliability
Out of Service
Units
Property List
AV11
"MTD Max Power"
ANALOG_VALUE (2)
Current reading
0
Normal (0)
NO_FAULT_DETECTED (0)
FALSE (0)
Kilojoule (17)
BACnetObjectIdentifier
CharacterString
BACnetObjectType
Real
BACnetStatusFlags
BACnetEventState
BACnetReliability
Boolean
BACnetEngineeringUnits
BACnetARRAY[N] of BACnetPropertyIdentifier
Read
Read
Read
Read
Read
Read
Read
Read/Write
Read/Write
Read
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Present Value
Status Flags
Event State
Reliability
Out of Service
Units
Property List
AV12
"MTD Min Power"
ANALOG_VALUE (2)
Current reading
0
Normal (0)
NO_FAULT_DETECTED (0)
FALSE (0)
Kilojoule (17)
BACnetObjectIdentifier
CharacterString
BACnetObjectType
Real
BACnetStatusFlags
BACnetEventState
BACnetReliability
Boolean
BACnetEngineeringUnits
BACnetARRAY[N] of BACnetPropertyIdentifier
Read
Read
Read
Read
Read
Read
Read
Read/Write
Read/Write
Read