Dwarf Connection X.LiNK-XS3 User Manual Download Page 12

CAUTION!

For a long product life, we highly recomment NOT to operate your DC-LINK 

with permanently switched off fans. Whenever you are operating your 

devices without cooling, monitor the temperature and make cooling 

breaks­when­the­indicator­on­your­display­is­flashing­(60°C­/­140°F).

THE DEVICES DO NOT HAVE AN EMERGENCY OUT!

If you allow your devices to get too hot, you might cause serious damage of 

your equipment.

Metadata Cross Translation*

Camera metadata is transmitted through SDI only. On your XS3 HDMI receiver, 

the incoming information is translated into HDMI, which allows you to use meta-

data bound features, like automatic recording on your monitor.

Fan Control & Cinema Mode

Fan control allows you to turn the fans of the devices on or off to keep them 

cool but also prevent unwanted noise. Press MENU to navigate to the fan menu 

and select the desired state by using + or - .

AUTO indicates cinema mode, which triggers the fans using the start / stop flags 

of the camera. Once you hit record, the fan will stop, ensuring total silence. 

After recording, it will turn back on automatically. Cinema mode is bound to 

metadata support.*

√ switches the fans on permanently. X switches the fans off.

Encryption
In encryption mode, the transmitter sends an encoded signal that only linked 

receivers can read, making it easy to protect confidential content that is not 

meant for everyone’s eyes.

To activate encryption mode, press the MENU button until ENC is flashing. Use + 

or – to check either 

ENC or  

X

ENC and confirm with MENU.

To link your devices, set your transmitter and all the receivers to the same chan-

nel, then activate encryption on your transmitter. All receivers will follow into en-

cryption mode automatically. Settings remain active  after turning your devices 

off. This means that ENC can be prepared prior to shooting and will stay active 

unless you turn it off.

A linked receiver does not HAVE to stay linked. To take a receiver out of the en-

crypted system, simply turn off ENC. Then you can easily access another (unen-

crypted) transmitter’s images by choosing the referring channel within seconds. 

To link back to the previous (encrypted) transmitter, turn ENC on again.

*  Due to various standards metadata compatibility can be limited. Improvements are made constant-

ly. Please check latest firmware.

12

Summary of Contents for X.LiNK-XS3

Page 1: ...user maNual X LiNK XS3...

Page 2: ...Characteristics 6 Product Description 7 Assembly Guide 8 Scope of Delivery 9 Operation 9 Features 10 Maintenance 14 Troubleshooting 14 Technical Specifications 15 Notes 16 In all EU member states oper...

Page 3: ...uction without the written permission of the copyright owner is prohibited in part or in full All third party brands or copyrights mentioned in this manual are the property of their respective owners...

Page 4: ...eratures of 20 and 60 C 0 and 140 F Ensure sufficient ventilation when operating your DC LINK system in warm temperatures to prevent overheating Do not leave your devices in places in which the temper...

Page 5: ...certain environ ments Your devices are designed to comply with regulations governing radio frequency emissions but use of such systems can negatively affect other elect ronic equipment RECYCLING Plea...

Page 6: ...port 1 1 or 1 n transmissions with up to four parallel systems Limited Metadata Support Start Stop Timecode Metadata Cross Translation SDI to HMDI High grade aluminium casing extremely durable and hea...

Page 7: ...ceiver 1 1 4 Thread 2 Control Buttons 3 Menu Button 4 OLED display 5 Power Switch 6 HDMI OUT 7 DC IN 7 2 18V 8 Mini USB For firmware upgrade 9 NPF Battery Port 10 Nato Rail 11 NPF Sandwich Plate 12 Ba...

Page 8: ...8...

Page 9: ...closed D Tap cables or a NPF battery to power your receiver Only use 4 pin cables provided by DwarfConnection to power your DC LINK system Other cables might cause damage of your products 2 Turn on yo...

Page 10: ...ngs use MENU to navigate to the desired Sub Menu Then use and to make your changes and confirm with MENU Received Signal Strength Indicator RSSI The RSSI display shows the strength of the signal allow...

Page 11: ...equency set the number shows the chan nel The channels used by DwarfConnection transmitters do NOT show a letter Therefore when working with a DC LINK transmitter choose from channel 0 to 9 on your re...

Page 12: ...ing it will turn back on automatically Cinema mode is bound to metadata support switches the fans on permanently X switches the fans off Encryption In encryption mode the transmitter sends an encoded...

Page 13: ...ncrypted systems is not possible You cannot slip into an encrypted wireless system if your receiver was not initi ally linked to the transmitter If you want to add a new receiver to an encrypted syste...

Page 14: ...fficient power Antennas Ensure antennas are not damaged and are firmly connected Please use the DC Scan to check Video connection cable Examine the transmitter s Video LED display If the LED is dark c...

Page 15: ...75mm 5 1 x 2 8 x 0 9 Weight 288 8g 10 2oz 376 6g 13 3oz Supported Video Formats 1080p 60 59 94 50 30 29 97 25 24 23 98 1080i 60 59 94 50 720p 60 59 94 50 1080p 60 59 94 50 30 29 97 25 24 23 98 1080i 6...

Page 16: ...Notes 16...

Page 17: ...Notes 17 EN...

Page 18: ...Notes 18...

Page 19: ...Notes 19 EN...

Page 20: ...www dwarfconnection com DwarfConnection GmbH Co KG M nzfeld 51 4810 Gmunden AUSTRIA 20...

Reviews: