25
3.11 Alarm
ALARM SETUP
(CTRL KEY)
NO PRI FUN IN OUT HOLD LATCH
1 1 001 NO OUT1 03 OFF
2 1 --- OFF OFF 03 OFF
3 1 --- OFF OFF 03 OFF
4 1 --- OFF OFF 03 OFF
DWELL : 03 SEC
ALARM OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)
NO (Number)
Alarm input number
PRI (Priority)
The lower number has a higher priority. (0 ~ 4)
FUN (Function) Stored function number to be called by an alarm.
IN (Input)
NO/NC – normally open/closed, OFF – ignore
OUT (Output)
OUT1 ~ OUT2 – 5VTTL output, OFF – no output
HOLD
Alarm will be held for the programmed time. (03 to 99 seconds)
LATCH ON – Alarm message will remain on the screen even though the
alarm input is deactivated.
OFF – Alarm message will disappear from the screen after
programmed hold time when alarm input is deactivated.
DWELL
Means the dwell time during multiple alarms, 03 to 99 seconds.
ALARM OUT SETUP
OUT1 : ALARM
OUT2 : 1 MIN
EXIT(ESC TO EXIT)
ALARM: Alarm output is operated during an alarm operation or by the short key of
the keyboard.
1 ~ 5 MIN (minute): Alarm output is operated during this set time only by the
function run of the PTZ menu or the short key of the keyboard.
NOTE: This 1 ~ 5 MIN setting is not operated by an alarm.
There are 5 priority levels. The function can be a Preset, Auto scan, Pattern, or Tour.
“0” is the highest priority. Lower priority alarms will not be serviced until the higher
priority alarms are completed. Alarms with equal priority will be serviced repeatedly
with the set dwell time.