Sheet 3 of 3
Step 1
Turn off mains power. Loosen and remove M10 Allen bolts and remove the
stirrup bracket from the main body.
Step 3
Reattach main floodlight body to the newly mounted stirrup. Adjust to the
desired angle then fully tighten M10 Allen bolts to fix in place. Unscrew M5 Allen
bolts on the top of the light to open the gear compartment lid.
Step 5
Tighten cable gland around power cable. Close the gear compartment and
re-tighten the M5 bolts ensuring they are fully tightened to maintain water
ingress rating.
Step 2
Position the stirrup bracket on the post top bracket, tighten the provided bolts
to 10Nm to fix them.
Step 4
Loosen cable gland and feed power cable through into the gear compartment.
Insert the live, neutral and ground wires in their respective ports on the terminal
block, tighten terminal block screws fully.
Step 6
Once cable routing has been completed and checked mains power can be
restored. For products with CMS expect a slight delay on initial power up.
LEDs contained within this luminaire shall only be replaced
by the manufacturer, their service agent or similar qualified
person.
3d50302
-08 - Issue 1
DW Windsor
Pindar Road, Hoddesdon, Hertfordshire, EN11 ODX
T: +44 (0) 1992 474600 | E: [email protected]
dwwindsor.com
The Sabre Range
LED Flood Light
Sabre 1, 2 and 3
NOTE!
Sabre Installation Steps | Stirrup Wall Mounting