background image

Sheet 2 of 3

Step 1

Turn off mains power. Loosen and remove M10 Allen bolts and remove the 
stirrup bracket from the main body. 

Step 3

Reattach main floodlight body to the newly mounted stirrup. Adjust to the 
desired angle then fully tighten M10 Allen bolts to fix in place. Unscrew M5 Allen 
bolts on the top of the light to open the gear compartment lid.

Step 5

Tighten cable gland around power cable. Close the gear compartment and 
re-tighten the M5 bolts ensuring they are fully tightened to maintain water 
ingress rating.

Step 2 

Position the stirrup bracket on the wall, use the existing holes in the stirrup 
bracket as guides, drill holes and insert anchors. Tighten screws into anchor 
points to fix stirrup securely to wall. 

Step 4

Loosen cable gland and feed power cable through into the gear compartment. 
Insert the live, neutral and ground wires in their respective ports on the terminal 
block, tighten terminal block screws fully. 

Step 6

Once cable routing has been completed and checked mains power can be 
restored. For products with CMS expect a slight delay on initial power up.

LEDs contained within this luminaire shall only be replaced 
by the manufacturer, their service agent or similar qualified 
person.

3d50302

-08 - Issue 1

DW Windsor

Pindar Road, Hoddesdon, Hertfordshire, EN11 ODX
T: +44 (0) 1992 474600  |  E: [email protected]
dwwindsor.com

The Sabre Range

LED Flood Light

Sabre 1, 2 and 3

NOTE!

Sabre Installation Steps | Stirrup Wall Mounting

Reviews: