3.8.2 Alarm Input Port
Please refer to the following sheet for more information.
z
4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)
z
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
z
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
z
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
z
Use the same ground with that of DVR if you use external power to the alarm device.
z
Use the contro12V power to reset the smoke sensor remotely.
Figure 3-7
3.8.3 Alarm Output Port
z
Provide power to peripheral alarm device.
z
To avoid overloading, please read the following relay parameters sheet carefully.
z
For contro12V, it can be used to provide power to devices such as reset smoke
sensor.
z
RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model:
JRC-27F
Material of the
touch
Silver
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Maximum switch voltage
250VAC, 220VDC
Rating
(
Resistance
Load
)
Maximum switch currency
1A
Between touches with same
polarity
1000VAC 1minute
Between touches with different
polarity
1000VAC 1minute
Insulation
Between touch and winding
1000VAC 1minute
Surge voltage
Between touches with same
polarity
1500V (10×160us)
Length of open
time
3ms max
Summary of Contents for 2U Series
Page 1: ...1 2U Series Standalone DVR User s Manual Version 3 0 ...
Page 25: ...25 Installation Mode Desktop rack installation ...
Page 44: ...44 Figure 3 9 ...
Page 59: ...59 Figure 4 21 Figure 4 22 Figure 4 23 Figure 4 24 4 5 3 Video Loss ...
Page 62: ...62 Figure 4 27 Figure 4 28 Figure 4 29 Figure 4 30 ...
Page 107: ...107 Figure 6 11 ...
Page 163: ...163 Samsung HA101UJ CE 1T SATA ...