Defect

Cause

Remedy

1 Power supply is not correct

1.1 Check the tension.

2 Thermal switch tripped (only for versions
with alternated tension).

2.1  Verify  the  causes  that  have
produced it.

3 Operation with not allowed substances.

3.1 Call service.

A. Pumps doesn't

operate

4 Motor winding fault.

4.1 Call service.

1 Power supply is not correct

1.1 Check the tension.

2 Outlet obstructed.

2.1 Check the pipes.

B. The pump

doesn't reach
the declared
pressure.

3 Gaskets deterioration

3.1 Replace Gaskets

1 Gaskets deterioration

1.1 Replace Gaskets

2 Motor bearings damaged.

2.1 Call service.

3 Outlet obstructed.

3.1 Check the pipes.

C. The pumps is

noisy.

4  Vibrations  transmitted  to  the  pump
from the system

4.1 Install shock mounts

1 Insufficient environmental ventilation

1.1 Install an auxiliary fan.

2 FAN motor rout.

2.1 Call service.

3 Power supply is not correct

3.1 Call service.

D. High pump

temperatur.

4 Overcoming of the service factor

4.1 See table

DECLARATION OF THE MANUFACTURER

The society

:

D.V.P. Vacuum Technology S.r.l

.   Via Vinca 5

40016 SAN GIORGIO DI PIANO (BO) ITALY

in the person of his President

Mario Zucchini

FORBID

the operation of the diaphragm

vacuum pumps type:

MA.15

9215001 – 9215002

MA.15S

9216007 – 9216008

MV.30P

9217007 – 9217008

before the machine in which they will be

incorporated will be declared compliant

with the dispositions of the

directives 98/37/CEE, 73/23/CEE, 89/336/CEE

and following modifications.

Date and place
19/05/03   S. Giorgio di Piano

Mario Zucchini

CE DECLARATION OF CONFORMITY'

The society:

D.V.P. Vacuum Technology S.r.l

.   Via Vinca 5

40016 SAN GIORGIO DI PIANO (BO) ITALY

it declares under its sole exclusive responsibility

that the vacuum

diaphragm pumps types:

MA 15

9215003 – 9215004 – 9215005 - 9215006

MA 15S

9216001 – 9216002 – 9216003

9216004 – 9216005 - 9216006

MA 30P

9217001 – 9217002 – 9217003

9217004 – 9217005 - 9217006

to which this declaration refers comply with

:

directives 98/37/CEE, 73/23/CEE, 89/336/CEE and

following modifications

Date and place
19/05/03   S. Giorgio di Piano

Mario Zucchini

D.V.P. Vacuum Technology S.r.l.
Via Vinca 5, 40016 S. Giorgio di Piano 40016 (BO) ITALY
Tel (051) 665.00.20 Fax (051) 665.04.16

http://www.dvp.it;

 e-mail: 

[email protected]

Summary of Contents for 9215001

Page 1: ...MA 15S MV 15S MA 30P MV 30P MA 15 230V 50 60Hz 12 24V cc MA 15S 220 240V 50 60Hz 12 24V cc MV 15S MV 30P MA30 P 220 240V 50 60Hz 220 240V 50 60Hz 12 24V cc 1 ASPIRAZIONE 5 VENTOLA RAFFREDDAMENTO 2 SC...

Page 2: ...non sia danneggiato in caso contrario controllate che la pompa funzioni correttamente In caso di danni inviate reclamo scritto al trasportatore indicando anche il numero di bolla data e notificate l i...

Page 3: ...one non raggiunge il valore nominale in pochi secondi deve scattare l interruttore termico installato a protezione della pompa solo per versioni a corrente alternata 3 3 Spegnimento Prima di spegnere...

Page 4: ...atura pompa elevata 4 Superamento del fattore di servizio Vedere tabella DICHIARAZIONE DEL FABBRICANTE La societ sotto indicata D V P Vacuum Technology S r l Via Vinca 5 40016 SAN GIORGIO DI PIANO BO...

Page 5: ......

Page 6: ...CUUM PUMPS MA 15 MA 15S MV 15S MA 30P MV 30P MA 15 230V 50 60Hz 12 24V cc MA 15S 220 240V 50 60Hz 12 24V cc MV 15S MV 30P MA30 P 220 240V 50 60Hz 220 240V 50 60Hz 12 24V cc 1 INLET 5 COOLING FAN 2 OUT...

Page 7: ...or notice 2 INSTALLATION 2 1 Unpack Check that the pack is not damaged on the contrary check that the pump operates correctly In case of damages please send claim in writing to the carrier also pointi...

Page 8: ...pump may reach high temperatures when operating After start up the pump may run slower than regular r p m if ambient temperature is lower than that permitted If nominal r p m is not reached within a f...

Page 9: ...table DECLARATION OF THE MANUFACTURER The society D V P Vacuum Technology S r l Via Vinca 5 40016 SAN GIORGIO DI PIANO BO ITALY in the person of his President Mario Zucchini FORBID the operation of th...

Reviews: