17
DVDO-Xtend-TX100_V1.0.0
DVDO
DVDO-Xtend-TX100 3 x 1 HDBT Wall-plate Transmitter
User Manual
“DVDO Product Configuration Tool” menus are described below:
•
Get current settings:
Get the current settings of the sink device.
•
Baud rate:
Choose the correct baud rate according to the device, then click
“Connect” to connect with the sink device.
Note:
This might be different than the setting of 115200 above and is
determined by the sink device you are connecting to.
•
Power on:
Pre-load and store the command for “power on” to a sink device,
then click “Send” to send and store it on the device.
•
Power off:
Pre-load and store the command for “power off” to a sink device,
then click “Send” to send and store it on the device.
Note:
If the sink device requires hex commands, make sure the Hex box is
checked.
•
Delay:
Set delay time (1~30minutes) the sink device will power off
automatically after it cannot detect the input signal, click “set” to take effect.
•
Set Terminator:
Select the command ending after each API command that
you are sending from the transmitter or receiver to the sink device. Then
click “Set” to take effect.
•
Set Relay Mode:
Set relay mode for the sink device.
Latch –relay closes and latches when it is triggered;
Momentary –only closes for a moment and then opens after it is triggered.
The pulse time can be set from 1 to 10 seconds, default setting is 3s.
Then click “Set” to take effect.