HDI-03-W
Mar ‘15
- 12 -
Compressor Unit Accessories
‘AD-9400’ Pneumatic Autodrain.
The ‘AD-9400’ Pneumatic Autodrain is designed to drain moisture from the Compressor Tank each time the Unit
reaches maximum pressures and shuts off. It receives its signal as the Unit unloads once the Unit has shut down.
‘KK-9840-1’ Electronic Autodrain.
The ‘KK-9840-1’ Electronic Autodrain is designed to drain moisture from the Compressor Tank based on an
internal timer. The timer is an electrical device which requires 120-60-1 power to operate, and can be plugged into
a standard outlet. A 6 foot (1.8 m) power cord is supplied.
‘KK-9860’ Zero Loss Autodrain.
The ‘KK-9860’ Zero Loss Autodrain is designed to drain moisture from the Compressor Tank once the cavity
inside the Autodrain has become full. This eliminates the unnecessary draining of the Tank and purging of
compressed air. The Autodrain is an electrical device that requires a 120-60-1 power supply, and is supplied with
a 6 foot (1.8 m) power cord.
Specifications.
Maximum working pressure of 200 psi (13.8 Bar).
Minimum working pressure of 30 psi (2.1 Bar).
Will not operate in temperatures below freezing.
Maintenance.
Service/maintenance can only be done when the drain is
not under pressure.
The internal screens must be cleaned periodically.
The ‘RK-AD-9400’ Repair Kit is available.
Drain
Port
Reservoir
Signal from
Unloader
Moisture from
Tank
Specifications.
Maximum working pressure of 230 psi (16 Bar).
Includes manual Ball Valve and Filter.
Drain duration can be set between .05 to 10 seconds.
Operating cycle time (time between discharges) can be
set between 1 to 45 minutes.
UL and CSA approved.
Will not operate in temperatures below freezing.
Maintenance.
Service/maintenance can only be done when the drain is
not under pressure.
The internal wire mesh filter must be cleaned
periodically.
Ball
Valve
Internal Wire
Mesh Filter
Electronic
Timer
Condensate
Discharge
Specifications.
Maximum working pressure of 175 psi (12 Bar).
Includes manual Ball Valve and Filter.
IP65 Electrical Protection Rating.
Will not operate in temperatures below freezing.
Maintenance.
Service/maintenance can only be done when the drain is not under
pressure.
The internal wire mesh filter must be cleaned periodically.